Radial streak artifact reduction using phased array beamforming

Sagar Mandava, Mahesh B. Keerthivasan, Diego R Martin, Maria I Altbach, Ali Bilgin

Research output: Contribution to journalArticle

Abstract

Purpose: A new method for streak artifact reduction in radial MRI based on phased array filtering. Theory: Radial imaging in applications that require large fields-of-view can be susceptible to streaking artifacts due to gradient nonlinearities. Coil removal methods prune the coils contributing the most to streaking artifacts at the expense of signal loss. Phased array beamforming is a form of spatial filtering used to suppress unwanted signals. The proposed method uses interference covariance generated from the streaking artifact samples which are manually extracted with phased array beamforming to suppress streaking in the images. Methods: The performance of the proposed method was evaluated on abdomen radial fast spin echo images acquired on a 1.5T Siemens scanner and compared with previously proposed methods. Results: Our results demonstrate that the proposed method can effectively suppress streaking artifacts without any noticeable loss in signal levels. Coil removal methods can suppress streaks as well but they may incur significant signal loss due to coil pruning. Quantitative metrics also demonstrate the superiority of the proposed method over earlier methods. Conclusion: The use of interference covariance with phased array beamforming can help reduce streaking artifacts.

Original languageEnglish (US)
JournalMagnetic Resonance in Medicine
DOIs
StatePublished - Jan 1 2019

Fingerprint

Artifacts
Abdomen

Keywords

  • abdominal imaging
  • beamforming
  • coil selection
  • phased array
  • radial MRI
  • streaking artifacts

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Radial streak artifact reduction using phased array beamforming. / Mandava, Sagar; Keerthivasan, Mahesh B.; Martin, Diego R; Altbach, Maria I; Bilgin, Ali.

In: Magnetic Resonance in Medicine, 01.01.2019.

Research output: Contribution to journalArticle

@article{a8f2f359101a4945b7a55e8540cf9a0b,
title = "Radial streak artifact reduction using phased array beamforming",
abstract = "Purpose: A new method for streak artifact reduction in radial MRI based on phased array filtering. Theory: Radial imaging in applications that require large fields-of-view can be susceptible to streaking artifacts due to gradient nonlinearities. Coil removal methods prune the coils contributing the most to streaking artifacts at the expense of signal loss. Phased array beamforming is a form of spatial filtering used to suppress unwanted signals. The proposed method uses interference covariance generated from the streaking artifact samples which are manually extracted with phased array beamforming to suppress streaking in the images. Methods: The performance of the proposed method was evaluated on abdomen radial fast spin echo images acquired on a 1.5T Siemens scanner and compared with previously proposed methods. Results: Our results demonstrate that the proposed method can effectively suppress streaking artifacts without any noticeable loss in signal levels. Coil removal methods can suppress streaks as well but they may incur significant signal loss due to coil pruning. Quantitative metrics also demonstrate the superiority of the proposed method over earlier methods. Conclusion: The use of interference covariance with phased array beamforming can help reduce streaking artifacts.",
keywords = "abdominal imaging, beamforming, coil selection, phased array, radial MRI, streaking artifacts",
author = "Sagar Mandava and Keerthivasan, {Mahesh B.} and Martin, {Diego R} and Altbach, {Maria I} and Ali Bilgin",
year = "2019",
month = "1",
day = "1",
doi = "10.1002/mrm.27689",
language = "English (US)",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",

}

TY - JOUR

T1 - Radial streak artifact reduction using phased array beamforming

AU - Mandava, Sagar

AU - Keerthivasan, Mahesh B.

AU - Martin, Diego R

AU - Altbach, Maria I

AU - Bilgin, Ali

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Purpose: A new method for streak artifact reduction in radial MRI based on phased array filtering. Theory: Radial imaging in applications that require large fields-of-view can be susceptible to streaking artifacts due to gradient nonlinearities. Coil removal methods prune the coils contributing the most to streaking artifacts at the expense of signal loss. Phased array beamforming is a form of spatial filtering used to suppress unwanted signals. The proposed method uses interference covariance generated from the streaking artifact samples which are manually extracted with phased array beamforming to suppress streaking in the images. Methods: The performance of the proposed method was evaluated on abdomen radial fast spin echo images acquired on a 1.5T Siemens scanner and compared with previously proposed methods. Results: Our results demonstrate that the proposed method can effectively suppress streaking artifacts without any noticeable loss in signal levels. Coil removal methods can suppress streaks as well but they may incur significant signal loss due to coil pruning. Quantitative metrics also demonstrate the superiority of the proposed method over earlier methods. Conclusion: The use of interference covariance with phased array beamforming can help reduce streaking artifacts.

AB - Purpose: A new method for streak artifact reduction in radial MRI based on phased array filtering. Theory: Radial imaging in applications that require large fields-of-view can be susceptible to streaking artifacts due to gradient nonlinearities. Coil removal methods prune the coils contributing the most to streaking artifacts at the expense of signal loss. Phased array beamforming is a form of spatial filtering used to suppress unwanted signals. The proposed method uses interference covariance generated from the streaking artifact samples which are manually extracted with phased array beamforming to suppress streaking in the images. Methods: The performance of the proposed method was evaluated on abdomen radial fast spin echo images acquired on a 1.5T Siemens scanner and compared with previously proposed methods. Results: Our results demonstrate that the proposed method can effectively suppress streaking artifacts without any noticeable loss in signal levels. Coil removal methods can suppress streaks as well but they may incur significant signal loss due to coil pruning. Quantitative metrics also demonstrate the superiority of the proposed method over earlier methods. Conclusion: The use of interference covariance with phased array beamforming can help reduce streaking artifacts.

KW - abdominal imaging

KW - beamforming

KW - coil selection

KW - phased array

KW - radial MRI

KW - streaking artifacts

UR - http://www.scopus.com/inward/record.url?scp=85061576160&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85061576160&partnerID=8YFLogxK

U2 - 10.1002/mrm.27689

DO - 10.1002/mrm.27689

M3 - Article

C2 - 30756432

AN - SCOPUS:85061576160

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

ER -