Real time monitoring of E.coli within potable water distributions systems

Syreeta Miles, Ryan Sinclair, Mark Riley, Ian L Pepper

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Majority of the parameters increases to an increase in E. coli concentrations Sensors did not respond to E. coli concentrations below 103 cfu/mL Sensors utilizing a light scattering method became saturated when the E. coli concentration was over 106 cfu/mL The BioSentry is not able to distinguish between a particulate and a microorganism TOC sensors respond to either media or high bacterial load.

Original languageEnglish (US)
Title of host publicationAmerican Water Works Association Annual Conference and Exposition 2010, ACE 2010, Papers
StatePublished - 2010
EventAmerican Water Works Association Annual Conference and Exposition 2010, ACE 2010 - Chicago, IL, United States
Duration: Jun 20 2010Jun 24 2010

Other

OtherAmerican Water Works Association Annual Conference and Exposition 2010, ACE 2010
CountryUnited States
CityChicago, IL
Period6/20/106/24/10

Fingerprint

distribution system
drinking water
monitoring
sensor
water
light scattering
microorganism
water distribution system
time

ASJC Scopus subject areas

  • Water Science and Technology
  • Public Administration

Cite this

Miles, S., Sinclair, R., Riley, M., & Pepper, I. L. (2010). Real time monitoring of E.coli within potable water distributions systems. In American Water Works Association Annual Conference and Exposition 2010, ACE 2010, Papers

Real time monitoring of E.coli within potable water distributions systems. / Miles, Syreeta; Sinclair, Ryan; Riley, Mark; Pepper, Ian L.

American Water Works Association Annual Conference and Exposition 2010, ACE 2010, Papers. 2010.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Miles, S, Sinclair, R, Riley, M & Pepper, IL 2010, Real time monitoring of E.coli within potable water distributions systems. in American Water Works Association Annual Conference and Exposition 2010, ACE 2010, Papers. American Water Works Association Annual Conference and Exposition 2010, ACE 2010, Chicago, IL, United States, 6/20/10.
Miles S, Sinclair R, Riley M, Pepper IL. Real time monitoring of E.coli within potable water distributions systems. In American Water Works Association Annual Conference and Exposition 2010, ACE 2010, Papers. 2010
Miles, Syreeta ; Sinclair, Ryan ; Riley, Mark ; Pepper, Ian L. / Real time monitoring of E.coli within potable water distributions systems. American Water Works Association Annual Conference and Exposition 2010, ACE 2010, Papers. 2010.
@inproceedings{3e2b5f651ae34c2bb62fb6942bd49347,
title = "Real time monitoring of E.coli within potable water distributions systems",
abstract = "Majority of the parameters increases to an increase in E. coli concentrations Sensors did not respond to E. coli concentrations below 103 cfu/mL Sensors utilizing a light scattering method became saturated when the E. coli concentration was over 106 cfu/mL The BioSentry is not able to distinguish between a particulate and a microorganism TOC sensors respond to either media or high bacterial load.",
author = "Syreeta Miles and Ryan Sinclair and Mark Riley and Pepper, {Ian L}",
year = "2010",
language = "English (US)",
isbn = "9781617389696",
booktitle = "American Water Works Association Annual Conference and Exposition 2010, ACE 2010, Papers",

}

TY - GEN

T1 - Real time monitoring of E.coli within potable water distributions systems

AU - Miles, Syreeta

AU - Sinclair, Ryan

AU - Riley, Mark

AU - Pepper, Ian L

PY - 2010

Y1 - 2010

N2 - Majority of the parameters increases to an increase in E. coli concentrations Sensors did not respond to E. coli concentrations below 103 cfu/mL Sensors utilizing a light scattering method became saturated when the E. coli concentration was over 106 cfu/mL The BioSentry is not able to distinguish between a particulate and a microorganism TOC sensors respond to either media or high bacterial load.

AB - Majority of the parameters increases to an increase in E. coli concentrations Sensors did not respond to E. coli concentrations below 103 cfu/mL Sensors utilizing a light scattering method became saturated when the E. coli concentration was over 106 cfu/mL The BioSentry is not able to distinguish between a particulate and a microorganism TOC sensors respond to either media or high bacterial load.

UR - http://www.scopus.com/inward/record.url?scp=84871447218&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84871447218&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84871447218

SN - 9781617389696

BT - American Water Works Association Annual Conference and Exposition 2010, ACE 2010, Papers

ER -