Resistance to blood flow in microvessels in vivo

A. R. Pries, Timothy W Secomb, T. Geßner, M. B. Sperandio, J. F. Gross, P. Gaehtgens

Research output: Contribution to journalArticle

391 Citations (Scopus)

Abstract

Resistance to blood flow through peripheral vascular beds strongly influences cardiovascular function and transport to tissue. For a given vascular architecture, flow resistance is determined by the rheological behavior of blood flowing through microvessels. A new approach for calculating the contribution of blood rheology to microvascular flow resistance is presented. Morphology (diameter and length), flow velocity, hematocrit, and topological position were determined for all vessel segments (up to 913) of terminal microcirculatory networks in the rat mesentery by intravital microscopy. Flow velocity and hematocrit were also predicted from mathematical flow simulations, in which the assumed dependence of flow resistance on diameter, hematocrit, and shear rate was optimized to minimize the deviation between measured and predicted values. For microvessels with diameters below ≃40 μm, the resulting flow resistances are markedly higher and show a stronger dependence on hematocrit than previously estimated from measurements of blood flow in narrow glass tubes. For example, flow resistance in 10-μm microvessels at normal hematocrit is found to exceed that of a corresponding glass tube by a factor of ≃4. In separate experiments, flow resistance of microvascular networks was estimated from direct measurements of total pressure drop and volume flow, at systemic hematocrits intentionally varied from 0.08 to 0.68. The results agree closely with predictions based on the above-optimized resistance but not with predictions based on glass-tube data. The unexpectedly high flow resistance in small microvessels may be related to interactions between blood components and the inner vessel surface that do not occur in smooth-walled tubes.

Original languageEnglish (US)
Pages (from-to)904-915
Number of pages12
JournalCirculation Research
Volume75
Issue number5
StatePublished - Nov 1994

Fingerprint

Microvessels
Hematocrit
Glass
Blood Vessels
Mesentery
Rheology
Pressure

Keywords

  • blood viscosity
  • hematocrit
  • microvascular networks
  • peripheral resistance
  • pressure drop

ASJC Scopus subject areas

  • Physiology
  • Cardiology and Cardiovascular Medicine

Cite this

Pries, A. R., Secomb, T. W., Geßner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994). Resistance to blood flow in microvessels in vivo. Circulation Research, 75(5), 904-915.

Resistance to blood flow in microvessels in vivo. / Pries, A. R.; Secomb, Timothy W; Geßner, T.; Sperandio, M. B.; Gross, J. F.; Gaehtgens, P.

In: Circulation Research, Vol. 75, No. 5, 11.1994, p. 904-915.

Research output: Contribution to journalArticle

Pries, AR, Secomb, TW, Geßner, T, Sperandio, MB, Gross, JF & Gaehtgens, P 1994, 'Resistance to blood flow in microvessels in vivo', Circulation Research, vol. 75, no. 5, pp. 904-915.
Pries AR, Secomb TW, Geßner T, Sperandio MB, Gross JF, Gaehtgens P. Resistance to blood flow in microvessels in vivo. Circulation Research. 1994 Nov;75(5):904-915.
Pries, A. R. ; Secomb, Timothy W ; Geßner, T. ; Sperandio, M. B. ; Gross, J. F. ; Gaehtgens, P. / Resistance to blood flow in microvessels in vivo. In: Circulation Research. 1994 ; Vol. 75, No. 5. pp. 904-915.
@article{19f379c44c144fbdaa18234ec3b04c9f,
title = "Resistance to blood flow in microvessels in vivo",
abstract = "Resistance to blood flow through peripheral vascular beds strongly influences cardiovascular function and transport to tissue. For a given vascular architecture, flow resistance is determined by the rheological behavior of blood flowing through microvessels. A new approach for calculating the contribution of blood rheology to microvascular flow resistance is presented. Morphology (diameter and length), flow velocity, hematocrit, and topological position were determined for all vessel segments (up to 913) of terminal microcirculatory networks in the rat mesentery by intravital microscopy. Flow velocity and hematocrit were also predicted from mathematical flow simulations, in which the assumed dependence of flow resistance on diameter, hematocrit, and shear rate was optimized to minimize the deviation between measured and predicted values. For microvessels with diameters below ≃40 μm, the resulting flow resistances are markedly higher and show a stronger dependence on hematocrit than previously estimated from measurements of blood flow in narrow glass tubes. For example, flow resistance in 10-μm microvessels at normal hematocrit is found to exceed that of a corresponding glass tube by a factor of ≃4. In separate experiments, flow resistance of microvascular networks was estimated from direct measurements of total pressure drop and volume flow, at systemic hematocrits intentionally varied from 0.08 to 0.68. The results agree closely with predictions based on the above-optimized resistance but not with predictions based on glass-tube data. The unexpectedly high flow resistance in small microvessels may be related to interactions between blood components and the inner vessel surface that do not occur in smooth-walled tubes.",
keywords = "blood viscosity, hematocrit, microvascular networks, peripheral resistance, pressure drop",
author = "Pries, {A. R.} and Secomb, {Timothy W} and T. Ge{\ss}ner and Sperandio, {M. B.} and Gross, {J. F.} and P. Gaehtgens",
year = "1994",
month = "11",
language = "English (US)",
volume = "75",
pages = "904--915",
journal = "Circulation Research",
issn = "0009-7330",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

TY - JOUR

T1 - Resistance to blood flow in microvessels in vivo

AU - Pries, A. R.

AU - Secomb, Timothy W

AU - Geßner, T.

AU - Sperandio, M. B.

AU - Gross, J. F.

AU - Gaehtgens, P.

PY - 1994/11

Y1 - 1994/11

N2 - Resistance to blood flow through peripheral vascular beds strongly influences cardiovascular function and transport to tissue. For a given vascular architecture, flow resistance is determined by the rheological behavior of blood flowing through microvessels. A new approach for calculating the contribution of blood rheology to microvascular flow resistance is presented. Morphology (diameter and length), flow velocity, hematocrit, and topological position were determined for all vessel segments (up to 913) of terminal microcirculatory networks in the rat mesentery by intravital microscopy. Flow velocity and hematocrit were also predicted from mathematical flow simulations, in which the assumed dependence of flow resistance on diameter, hematocrit, and shear rate was optimized to minimize the deviation between measured and predicted values. For microvessels with diameters below ≃40 μm, the resulting flow resistances are markedly higher and show a stronger dependence on hematocrit than previously estimated from measurements of blood flow in narrow glass tubes. For example, flow resistance in 10-μm microvessels at normal hematocrit is found to exceed that of a corresponding glass tube by a factor of ≃4. In separate experiments, flow resistance of microvascular networks was estimated from direct measurements of total pressure drop and volume flow, at systemic hematocrits intentionally varied from 0.08 to 0.68. The results agree closely with predictions based on the above-optimized resistance but not with predictions based on glass-tube data. The unexpectedly high flow resistance in small microvessels may be related to interactions between blood components and the inner vessel surface that do not occur in smooth-walled tubes.

AB - Resistance to blood flow through peripheral vascular beds strongly influences cardiovascular function and transport to tissue. For a given vascular architecture, flow resistance is determined by the rheological behavior of blood flowing through microvessels. A new approach for calculating the contribution of blood rheology to microvascular flow resistance is presented. Morphology (diameter and length), flow velocity, hematocrit, and topological position were determined for all vessel segments (up to 913) of terminal microcirculatory networks in the rat mesentery by intravital microscopy. Flow velocity and hematocrit were also predicted from mathematical flow simulations, in which the assumed dependence of flow resistance on diameter, hematocrit, and shear rate was optimized to minimize the deviation between measured and predicted values. For microvessels with diameters below ≃40 μm, the resulting flow resistances are markedly higher and show a stronger dependence on hematocrit than previously estimated from measurements of blood flow in narrow glass tubes. For example, flow resistance in 10-μm microvessels at normal hematocrit is found to exceed that of a corresponding glass tube by a factor of ≃4. In separate experiments, flow resistance of microvascular networks was estimated from direct measurements of total pressure drop and volume flow, at systemic hematocrits intentionally varied from 0.08 to 0.68. The results agree closely with predictions based on the above-optimized resistance but not with predictions based on glass-tube data. The unexpectedly high flow resistance in small microvessels may be related to interactions between blood components and the inner vessel surface that do not occur in smooth-walled tubes.

KW - blood viscosity

KW - hematocrit

KW - microvascular networks

KW - peripheral resistance

KW - pressure drop

UR - http://www.scopus.com/inward/record.url?scp=0027985612&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027985612&partnerID=8YFLogxK

M3 - Article

C2 - 7923637

AN - SCOPUS:0027985612

VL - 75

SP - 904

EP - 915

JO - Circulation Research

JF - Circulation Research

SN - 0009-7330

IS - 5

ER -