Cooling must be supplied for greenhouses located in semiarid climates most of the year to provide desired climate conditions for year-round crop production. High-pressure fogging systems have shown promising results for cooling, however the lack of effective control strategies, especially under passive ventilation, have limited their use. In this study, a new proposed climate control strategy, which considers the contribution on cooling and humidification from plants, is tested through simulation. The developed strategy using variable pressure fogging (VPF) and variable vent configurations was compared to a constant pressure fogging (CPF), fixed vents cooling strategy. In both cases, the control of fog was based on vapor pressure deficit (VPD) set points. Results showed that on average, VPF based system was able to save 15.2% of water and consumed 10.1% less energy. Pump cycling was reduced by 78.5% and lower temperature and relative humidity fluctuations were achieved by adjusting fog rates through manipulating the system working pressure. Finally, simulations also showed that by reducing the number of nozzles, a smaller fogging rate was achieved and the system performance and savings on water and energy were enhanced during morning hours of operation.

Original languageEnglish (US)
Title of host publicationActa Horticulturae
Pages37-44
Number of pages8
Volume952
StatePublished - Jun 1 2012

Publication series

NameActa Horticulturae
Volume952
ISSN (Print)05677572

Fingerprint

greenhouses
climate
cooling
fog (meteorology)
energy
water
nozzles
semiarid zones
vapor pressure
pumps
crop production
relative humidity
temperature

Keywords

  • Cooling
  • Cooling strategies
  • Environment model
  • Evaporative cooling
  • Transpiration

ASJC Scopus subject areas

  • Horticulture

Cite this

Villarreal-Guerrero, F., Kacira, M., Fitz-Rodríguez, E., Giacomelli, G. A., Linker, R., Kubota, C., & Arbel, A. (2012). Simulation of fixed and variable fogging rates in a naturally ventilated greenhouse: Water and energy savings and stability of climate. In Acta Horticulturae (Vol. 952, pp. 37-44). (Acta Horticulturae; Vol. 952).

Simulation of fixed and variable fogging rates in a naturally ventilated greenhouse : Water and energy savings and stability of climate. / Villarreal-Guerrero, F.; Kacira, Murat; Fitz-Rodríguez, E.; Giacomelli, Gene A; Linker, R.; Kubota, Chieri; Arbel, A.

Acta Horticulturae. Vol. 952 2012. p. 37-44 (Acta Horticulturae; Vol. 952).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Villarreal-Guerrero, F, Kacira, M, Fitz-Rodríguez, E, Giacomelli, GA, Linker, R, Kubota, C & Arbel, A 2012, Simulation of fixed and variable fogging rates in a naturally ventilated greenhouse: Water and energy savings and stability of climate. in Acta Horticulturae. vol. 952, Acta Horticulturae, vol. 952, pp. 37-44.
Villarreal-Guerrero F, Kacira M, Fitz-Rodríguez E, Giacomelli GA, Linker R, Kubota C et al. Simulation of fixed and variable fogging rates in a naturally ventilated greenhouse: Water and energy savings and stability of climate. In Acta Horticulturae. Vol. 952. 2012. p. 37-44. (Acta Horticulturae).
Villarreal-Guerrero, F. ; Kacira, Murat ; Fitz-Rodríguez, E. ; Giacomelli, Gene A ; Linker, R. ; Kubota, Chieri ; Arbel, A. / Simulation of fixed and variable fogging rates in a naturally ventilated greenhouse : Water and energy savings and stability of climate. Acta Horticulturae. Vol. 952 2012. pp. 37-44 (Acta Horticulturae).
@inproceedings{4523146e48564c69b86e3190599b2184,
title = "Simulation of fixed and variable fogging rates in a naturally ventilated greenhouse: Water and energy savings and stability of climate",
abstract = "Cooling must be supplied for greenhouses located in semiarid climates most of the year to provide desired climate conditions for year-round crop production. High-pressure fogging systems have shown promising results for cooling, however the lack of effective control strategies, especially under passive ventilation, have limited their use. In this study, a new proposed climate control strategy, which considers the contribution on cooling and humidification from plants, is tested through simulation. The developed strategy using variable pressure fogging (VPF) and variable vent configurations was compared to a constant pressure fogging (CPF), fixed vents cooling strategy. In both cases, the control of fog was based on vapor pressure deficit (VPD) set points. Results showed that on average, VPF based system was able to save 15.2{\%} of water and consumed 10.1{\%} less energy. Pump cycling was reduced by 78.5{\%} and lower temperature and relative humidity fluctuations were achieved by adjusting fog rates through manipulating the system working pressure. Finally, simulations also showed that by reducing the number of nozzles, a smaller fogging rate was achieved and the system performance and savings on water and energy were enhanced during morning hours of operation.",
keywords = "Cooling, Cooling strategies, Environment model, Evaporative cooling, Transpiration",
author = "F. Villarreal-Guerrero and Murat Kacira and E. Fitz-Rodr{\'i}guez and Giacomelli, {Gene A} and R. Linker and Chieri Kubota and A. Arbel",
year = "2012",
month = "6",
day = "1",
language = "English (US)",
isbn = "9789066053380",
volume = "952",
series = "Acta Horticulturae",
pages = "37--44",
booktitle = "Acta Horticulturae",

}

TY - GEN

T1 - Simulation of fixed and variable fogging rates in a naturally ventilated greenhouse

T2 - Water and energy savings and stability of climate

AU - Villarreal-Guerrero, F.

AU - Kacira, Murat

AU - Fitz-Rodríguez, E.

AU - Giacomelli, Gene A

AU - Linker, R.

AU - Kubota, Chieri

AU - Arbel, A.

PY - 2012/6/1

Y1 - 2012/6/1

N2 - Cooling must be supplied for greenhouses located in semiarid climates most of the year to provide desired climate conditions for year-round crop production. High-pressure fogging systems have shown promising results for cooling, however the lack of effective control strategies, especially under passive ventilation, have limited their use. In this study, a new proposed climate control strategy, which considers the contribution on cooling and humidification from plants, is tested through simulation. The developed strategy using variable pressure fogging (VPF) and variable vent configurations was compared to a constant pressure fogging (CPF), fixed vents cooling strategy. In both cases, the control of fog was based on vapor pressure deficit (VPD) set points. Results showed that on average, VPF based system was able to save 15.2% of water and consumed 10.1% less energy. Pump cycling was reduced by 78.5% and lower temperature and relative humidity fluctuations were achieved by adjusting fog rates through manipulating the system working pressure. Finally, simulations also showed that by reducing the number of nozzles, a smaller fogging rate was achieved and the system performance and savings on water and energy were enhanced during morning hours of operation.

AB - Cooling must be supplied for greenhouses located in semiarid climates most of the year to provide desired climate conditions for year-round crop production. High-pressure fogging systems have shown promising results for cooling, however the lack of effective control strategies, especially under passive ventilation, have limited their use. In this study, a new proposed climate control strategy, which considers the contribution on cooling and humidification from plants, is tested through simulation. The developed strategy using variable pressure fogging (VPF) and variable vent configurations was compared to a constant pressure fogging (CPF), fixed vents cooling strategy. In both cases, the control of fog was based on vapor pressure deficit (VPD) set points. Results showed that on average, VPF based system was able to save 15.2% of water and consumed 10.1% less energy. Pump cycling was reduced by 78.5% and lower temperature and relative humidity fluctuations were achieved by adjusting fog rates through manipulating the system working pressure. Finally, simulations also showed that by reducing the number of nozzles, a smaller fogging rate was achieved and the system performance and savings on water and energy were enhanced during morning hours of operation.

KW - Cooling

KW - Cooling strategies

KW - Environment model

KW - Evaporative cooling

KW - Transpiration

UR - http://www.scopus.com/inward/record.url?scp=84863677966&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863677966&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84863677966

SN - 9789066053380

VL - 952

T3 - Acta Horticulturae

SP - 37

EP - 44

BT - Acta Horticulturae

ER -