Smartphone-Based Optofluidic Lab-on-a-Chip for Detecting Pathogens from Blood

C. Christopher Stemple, Scott V. Angus, Tu San Park, Jeong-Yeol Yoon

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

A novel smartphone-based detection device was created to detect infectious pathogens directly from diluted (10%) human whole blood. The model pathogen was histidine-rich protein 2 (HRP-2), an antigen specific to Plasmodium falciparum (malaria). Anti-HRP-2-conjugated submicrobeads were mixed with HRP-2-infused 10% blood in a lab-on-a-chip device. The white LED flash and the digital camera of the smartphone were used as light source and detector, which delivered light to and from the bead and blood mixture via optofluidic channels in the lab-on-a-chip. The optofluidic channels were angled at 45 degrees to capture the Mie scatter from the sample. Considering the absorption and scattering characteristics of blood (red/infrared preferred) and the Mie scatter simulations for microbead immunoagglutination (UV preferred), blue detection showed the best results. The detection limit was 1 pg/mL in 10% blood. The linear range was from 1 pg/mL to 10 ng/mL. A handheld device, easily attachable to a single smartphone, was finally designed and fabricated using optical mirrors and lenses and successfully detected the HRP-2 from 10% blood. The total assay time was approximately 10 min. The proposed device can potentially be used for detecting a wide range of blood infection with high sensitivity.

Original languageEnglish (US)
Pages (from-to)35-41
Number of pages7
JournalJournal of laboratory automation
Volume19
Issue number1
DOIs
StatePublished - Feb 2014

Fingerprint

Lab-on-a-chip
Smartphones
Pathogens
Blood
Proteins
Equipment and Supplies
Light
Falciparum Malaria
Digital cameras
Antigens
Photodetectors
Smartphone
Microspheres
Lenses
Light emitting diodes
Light sources
Limit of Detection
Assays
Scattering
Infrared radiation

Keywords

  • cell phone-based detection
  • histidine-rich protein 2
  • HRP-2
  • immunoagglutination
  • microfluidic
  • Mie scatter
  • Plasmodium falciparum

ASJC Scopus subject areas

  • Computer Science Applications
  • Medical Laboratory Technology

Cite this

Smartphone-Based Optofluidic Lab-on-a-Chip for Detecting Pathogens from Blood. / Stemple, C. Christopher; Angus, Scott V.; Park, Tu San; Yoon, Jeong-Yeol.

In: Journal of laboratory automation, Vol. 19, No. 1, 02.2014, p. 35-41.

Research output: Contribution to journalArticle

Stemple, C. Christopher ; Angus, Scott V. ; Park, Tu San ; Yoon, Jeong-Yeol. / Smartphone-Based Optofluidic Lab-on-a-Chip for Detecting Pathogens from Blood. In: Journal of laboratory automation. 2014 ; Vol. 19, No. 1. pp. 35-41.
@article{ea3cdbafed9a4da2ab3a44ea36aa5e98,
title = "Smartphone-Based Optofluidic Lab-on-a-Chip for Detecting Pathogens from Blood",
abstract = "A novel smartphone-based detection device was created to detect infectious pathogens directly from diluted (10{\%}) human whole blood. The model pathogen was histidine-rich protein 2 (HRP-2), an antigen specific to Plasmodium falciparum (malaria). Anti-HRP-2-conjugated submicrobeads were mixed with HRP-2-infused 10{\%} blood in a lab-on-a-chip device. The white LED flash and the digital camera of the smartphone were used as light source and detector, which delivered light to and from the bead and blood mixture via optofluidic channels in the lab-on-a-chip. The optofluidic channels were angled at 45 degrees to capture the Mie scatter from the sample. Considering the absorption and scattering characteristics of blood (red/infrared preferred) and the Mie scatter simulations for microbead immunoagglutination (UV preferred), blue detection showed the best results. The detection limit was 1 pg/mL in 10{\%} blood. The linear range was from 1 pg/mL to 10 ng/mL. A handheld device, easily attachable to a single smartphone, was finally designed and fabricated using optical mirrors and lenses and successfully detected the HRP-2 from 10{\%} blood. The total assay time was approximately 10 min. The proposed device can potentially be used for detecting a wide range of blood infection with high sensitivity.",
keywords = "cell phone-based detection, histidine-rich protein 2, HRP-2, immunoagglutination, microfluidic, Mie scatter, Plasmodium falciparum",
author = "Stemple, {C. Christopher} and Angus, {Scott V.} and Park, {Tu San} and Jeong-Yeol Yoon",
year = "2014",
month = "2",
doi = "10.1177/2211068213498241",
language = "English (US)",
volume = "19",
pages = "35--41",
journal = "JALA - Journal of the Association for Laboratory Automation",
issn = "2211-0682",
publisher = "SAGE Publications Inc.",
number = "1",

}

TY - JOUR

T1 - Smartphone-Based Optofluidic Lab-on-a-Chip for Detecting Pathogens from Blood

AU - Stemple, C. Christopher

AU - Angus, Scott V.

AU - Park, Tu San

AU - Yoon, Jeong-Yeol

PY - 2014/2

Y1 - 2014/2

N2 - A novel smartphone-based detection device was created to detect infectious pathogens directly from diluted (10%) human whole blood. The model pathogen was histidine-rich protein 2 (HRP-2), an antigen specific to Plasmodium falciparum (malaria). Anti-HRP-2-conjugated submicrobeads were mixed with HRP-2-infused 10% blood in a lab-on-a-chip device. The white LED flash and the digital camera of the smartphone were used as light source and detector, which delivered light to and from the bead and blood mixture via optofluidic channels in the lab-on-a-chip. The optofluidic channels were angled at 45 degrees to capture the Mie scatter from the sample. Considering the absorption and scattering characteristics of blood (red/infrared preferred) and the Mie scatter simulations for microbead immunoagglutination (UV preferred), blue detection showed the best results. The detection limit was 1 pg/mL in 10% blood. The linear range was from 1 pg/mL to 10 ng/mL. A handheld device, easily attachable to a single smartphone, was finally designed and fabricated using optical mirrors and lenses and successfully detected the HRP-2 from 10% blood. The total assay time was approximately 10 min. The proposed device can potentially be used for detecting a wide range of blood infection with high sensitivity.

AB - A novel smartphone-based detection device was created to detect infectious pathogens directly from diluted (10%) human whole blood. The model pathogen was histidine-rich protein 2 (HRP-2), an antigen specific to Plasmodium falciparum (malaria). Anti-HRP-2-conjugated submicrobeads were mixed with HRP-2-infused 10% blood in a lab-on-a-chip device. The white LED flash and the digital camera of the smartphone were used as light source and detector, which delivered light to and from the bead and blood mixture via optofluidic channels in the lab-on-a-chip. The optofluidic channels were angled at 45 degrees to capture the Mie scatter from the sample. Considering the absorption and scattering characteristics of blood (red/infrared preferred) and the Mie scatter simulations for microbead immunoagglutination (UV preferred), blue detection showed the best results. The detection limit was 1 pg/mL in 10% blood. The linear range was from 1 pg/mL to 10 ng/mL. A handheld device, easily attachable to a single smartphone, was finally designed and fabricated using optical mirrors and lenses and successfully detected the HRP-2 from 10% blood. The total assay time was approximately 10 min. The proposed device can potentially be used for detecting a wide range of blood infection with high sensitivity.

KW - cell phone-based detection

KW - histidine-rich protein 2

KW - HRP-2

KW - immunoagglutination

KW - microfluidic

KW - Mie scatter

KW - Plasmodium falciparum

UR - http://www.scopus.com/inward/record.url?scp=84887514842&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84887514842&partnerID=8YFLogxK

U2 - 10.1177/2211068213498241

DO - 10.1177/2211068213498241

M3 - Article

VL - 19

SP - 35

EP - 41

JO - JALA - Journal of the Association for Laboratory Automation

JF - JALA - Journal of the Association for Laboratory Automation

SN - 2211-0682

IS - 1

ER -