Abstract

Retinal imaging spectroscopy can provide functional maps using chromophore spectra. For example, oxygen saturation maps show ischemic areas from diabetes and venous occlusions. Obtaining retinal spatial-spectral data has been difficult due to saccades and long data acquisition times (>5 s). We present a snapshot imaging spectrometer with far-reaching applicability that acquires a complete spatial-spectral image cube in ∼3 ms from 450 to 700 nm with 50 bands, eliminating motion artifacts and pixel misregistration. Current retinal spectral imaging approaches are incapable of true snapshot operation over a wide spectral range with a large number of spectral bands. Coupled to a fundus camera, the instrument returns true color retinal images for comparison to standard fundus images and for image validation while the patient is still dilated. Oxygen saturation maps were obtained with a three-wavelength algorithm: for healthy subjects arteries were ∼95% and veins 30 to 35% less. The instrument is now undergoing clinical trials.

Original languageEnglish (US)
Article number014036-1
JournalJournal of Biomedical Optics
Volume12
Issue number1
DOIs
StatePublished - Jan 2007
Externally publishedYes

Fingerprint

Ophthalmology
ophthalmology
Oxygen
Imaging techniques
Saccades
Artifacts
retinal images
saturation
Veins
Spectrum Analysis
Healthy Volunteers
Eye movements
Arteries
Color
occlusion
imaging spectrometers
Clinical Trials
oxygen
spectral bands
Chromophores

Keywords

  • Oximetry
  • Retina
  • Spectral imaging
  • Spectroscopy

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials
  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology
  • Clinical Biochemistry

Cite this

Johnson, W. R., Wilson, D. W., Fink, W., Humayun, M., & Bearman, G. (2007). Snapshot hyperspectral imaging in ophthalmology. Journal of Biomedical Optics, 12(1), [014036-1]. https://doi.org/10.1117/1.2434950

Snapshot hyperspectral imaging in ophthalmology. / Johnson, William R.; Wilson, Daniel W.; Fink, Wolfgang; Humayun, Mark; Bearman, Greg.

In: Journal of Biomedical Optics, Vol. 12, No. 1, 014036-1, 01.2007.

Research output: Contribution to journalArticle

Johnson, WR, Wilson, DW, Fink, W, Humayun, M & Bearman, G 2007, 'Snapshot hyperspectral imaging in ophthalmology', Journal of Biomedical Optics, vol. 12, no. 1, 014036-1. https://doi.org/10.1117/1.2434950
Johnson, William R. ; Wilson, Daniel W. ; Fink, Wolfgang ; Humayun, Mark ; Bearman, Greg. / Snapshot hyperspectral imaging in ophthalmology. In: Journal of Biomedical Optics. 2007 ; Vol. 12, No. 1.
@article{780ab599d23e4abda3202c79624ace22,
title = "Snapshot hyperspectral imaging in ophthalmology",
abstract = "Retinal imaging spectroscopy can provide functional maps using chromophore spectra. For example, oxygen saturation maps show ischemic areas from diabetes and venous occlusions. Obtaining retinal spatial-spectral data has been difficult due to saccades and long data acquisition times (>5 s). We present a snapshot imaging spectrometer with far-reaching applicability that acquires a complete spatial-spectral image cube in ∼3 ms from 450 to 700 nm with 50 bands, eliminating motion artifacts and pixel misregistration. Current retinal spectral imaging approaches are incapable of true snapshot operation over a wide spectral range with a large number of spectral bands. Coupled to a fundus camera, the instrument returns true color retinal images for comparison to standard fundus images and for image validation while the patient is still dilated. Oxygen saturation maps were obtained with a three-wavelength algorithm: for healthy subjects arteries were ∼95{\%} and veins 30 to 35{\%} less. The instrument is now undergoing clinical trials.",
keywords = "Oximetry, Retina, Spectral imaging, Spectroscopy",
author = "Johnson, {William R.} and Wilson, {Daniel W.} and Wolfgang Fink and Mark Humayun and Greg Bearman",
year = "2007",
month = "1",
doi = "10.1117/1.2434950",
language = "English (US)",
volume = "12",
journal = "Journal of Biomedical Optics",
issn = "1083-3668",
publisher = "SPIE",
number = "1",

}

TY - JOUR

T1 - Snapshot hyperspectral imaging in ophthalmology

AU - Johnson, William R.

AU - Wilson, Daniel W.

AU - Fink, Wolfgang

AU - Humayun, Mark

AU - Bearman, Greg

PY - 2007/1

Y1 - 2007/1

N2 - Retinal imaging spectroscopy can provide functional maps using chromophore spectra. For example, oxygen saturation maps show ischemic areas from diabetes and venous occlusions. Obtaining retinal spatial-spectral data has been difficult due to saccades and long data acquisition times (>5 s). We present a snapshot imaging spectrometer with far-reaching applicability that acquires a complete spatial-spectral image cube in ∼3 ms from 450 to 700 nm with 50 bands, eliminating motion artifacts and pixel misregistration. Current retinal spectral imaging approaches are incapable of true snapshot operation over a wide spectral range with a large number of spectral bands. Coupled to a fundus camera, the instrument returns true color retinal images for comparison to standard fundus images and for image validation while the patient is still dilated. Oxygen saturation maps were obtained with a three-wavelength algorithm: for healthy subjects arteries were ∼95% and veins 30 to 35% less. The instrument is now undergoing clinical trials.

AB - Retinal imaging spectroscopy can provide functional maps using chromophore spectra. For example, oxygen saturation maps show ischemic areas from diabetes and venous occlusions. Obtaining retinal spatial-spectral data has been difficult due to saccades and long data acquisition times (>5 s). We present a snapshot imaging spectrometer with far-reaching applicability that acquires a complete spatial-spectral image cube in ∼3 ms from 450 to 700 nm with 50 bands, eliminating motion artifacts and pixel misregistration. Current retinal spectral imaging approaches are incapable of true snapshot operation over a wide spectral range with a large number of spectral bands. Coupled to a fundus camera, the instrument returns true color retinal images for comparison to standard fundus images and for image validation while the patient is still dilated. Oxygen saturation maps were obtained with a three-wavelength algorithm: for healthy subjects arteries were ∼95% and veins 30 to 35% less. The instrument is now undergoing clinical trials.

KW - Oximetry

KW - Retina

KW - Spectral imaging

KW - Spectroscopy

UR - http://www.scopus.com/inward/record.url?scp=34247609294&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34247609294&partnerID=8YFLogxK

U2 - 10.1117/1.2434950

DO - 10.1117/1.2434950

M3 - Article

C2 - 17343511

AN - SCOPUS:34247609294

VL - 12

JO - Journal of Biomedical Optics

JF - Journal of Biomedical Optics

SN - 1083-3668

IS - 1

M1 - 014036-1

ER -