Sources of error in the quantitative analysis of MRI scans

Elena M Plante, Lyn Turkstra

Research output: Contribution to journalArticle

37 Citations (Scopus)

Abstract

The increasing use of quantitative analysis of MRI scans in the literature has produced a need to identify potential sources of bias in such analysis procedures. Six sources of bias are demonstrated in this paper. These include bias attributable to partial volume effects, head tilt, plane of view, use of noncontiguous slices, contrast/intensity manipulations, and magnetic inhomogeneities. The magnitude of bias for each source varied according to whether a hemisphere or regions within a hemisphere were measured, with regional effects typically exceeding hemisphere effects.

Original languageEnglish (US)
Pages (from-to)589-595
Number of pages7
JournalMagnetic Resonance Imaging
Volume9
Issue number4
DOIs
StatePublished - 1991

Fingerprint

quantitative analysis
Research Design
hemispheres
Head
Magnetic Resonance Imaging
Chemical analysis
manipulators
inhomogeneity

Keywords

  • Bias
  • Brain
  • Measurement
  • Morphometric
  • MRI

ASJC Scopus subject areas

  • Biophysics
  • Clinical Biochemistry
  • Structural Biology
  • Radiology Nuclear Medicine and imaging
  • Condensed Matter Physics

Cite this

Sources of error in the quantitative analysis of MRI scans. / Plante, Elena M; Turkstra, Lyn.

In: Magnetic Resonance Imaging, Vol. 9, No. 4, 1991, p. 589-595.

Research output: Contribution to journalArticle

@article{3be28bddfd234f048e93244ea1ebb685,
title = "Sources of error in the quantitative analysis of MRI scans",
abstract = "The increasing use of quantitative analysis of MRI scans in the literature has produced a need to identify potential sources of bias in such analysis procedures. Six sources of bias are demonstrated in this paper. These include bias attributable to partial volume effects, head tilt, plane of view, use of noncontiguous slices, contrast/intensity manipulations, and magnetic inhomogeneities. The magnitude of bias for each source varied according to whether a hemisphere or regions within a hemisphere were measured, with regional effects typically exceeding hemisphere effects.",
keywords = "Bias, Brain, Measurement, Morphometric, MRI",
author = "Plante, {Elena M} and Lyn Turkstra",
year = "1991",
doi = "10.1016/0730-725X(91)90047-P",
language = "English (US)",
volume = "9",
pages = "589--595",
journal = "Magnetic Resonance Imaging",
issn = "0730-725X",
publisher = "Elsevier Inc.",
number = "4",

}

TY - JOUR

T1 - Sources of error in the quantitative analysis of MRI scans

AU - Plante, Elena M

AU - Turkstra, Lyn

PY - 1991

Y1 - 1991

N2 - The increasing use of quantitative analysis of MRI scans in the literature has produced a need to identify potential sources of bias in such analysis procedures. Six sources of bias are demonstrated in this paper. These include bias attributable to partial volume effects, head tilt, plane of view, use of noncontiguous slices, contrast/intensity manipulations, and magnetic inhomogeneities. The magnitude of bias for each source varied according to whether a hemisphere or regions within a hemisphere were measured, with regional effects typically exceeding hemisphere effects.

AB - The increasing use of quantitative analysis of MRI scans in the literature has produced a need to identify potential sources of bias in such analysis procedures. Six sources of bias are demonstrated in this paper. These include bias attributable to partial volume effects, head tilt, plane of view, use of noncontiguous slices, contrast/intensity manipulations, and magnetic inhomogeneities. The magnitude of bias for each source varied according to whether a hemisphere or regions within a hemisphere were measured, with regional effects typically exceeding hemisphere effects.

KW - Bias

KW - Brain

KW - Measurement

KW - Morphometric

KW - MRI

UR - http://www.scopus.com/inward/record.url?scp=0025944191&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025944191&partnerID=8YFLogxK

U2 - 10.1016/0730-725X(91)90047-P

DO - 10.1016/0730-725X(91)90047-P

M3 - Article

C2 - 1779731

AN - SCOPUS:0025944191

VL - 9

SP - 589

EP - 595

JO - Magnetic Resonance Imaging

JF - Magnetic Resonance Imaging

SN - 0730-725X

IS - 4

ER -