Subtraction of test mass angular noise in the LISA technology package interferometer

F. Guzmán Cervantes, F. Steier, G. Wanner, G. Heinzel, K. Danzmann

Research output: Contribution to journalArticle

9 Scopus citations

Abstract

When the position of a test mass in one dimension is measured with picometer accuracy, angular alignment jitter inevitably couples noise into the measurement. We present recent sensitivity measurements of the LISA technology package interferometer with articulated mirrors as test masses, actuated by piezo-electric transducers. The required longitudinal displacement resolution of 9 pm/√Hz above 3 mHz has been demonstrated with an angular noise that corresponds to the expected for on-orbit operation. The excess noise contribution of this test mass jitter onto the sensitive displacement readout was completely subtracted by fitting the angular interferometric data streams to the longitudinal displacement measurement. Thus, this cross-coupling constitutes no limitation to the required performance of the LISA technology package interferometry.

Original languageEnglish (US)
Pages (from-to)395-400
Number of pages6
JournalApplied Physics B: Lasers and Optics
Volume90
Issue number3-4
DOIs
StatePublished - Mar 1 2008
Externally publishedYes

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)
  • Physics and Astronomy(all)

Fingerprint Dive into the research topics of 'Subtraction of test mass angular noise in the LISA technology package interferometer'. Together they form a unique fingerprint.