The disinfection efficacy of a point-of-use water treatment system against bacterial, viral and protozoan waterborne pathogens

Morteza Abbaszadegan, Michaela N. Hasan, Charles P Gerba, Peter F. Roessler, Barth R. Wilson, Roy Kuennen, Eric Van Dellen

Research output: Contribution to journalArticle

56 Citations (Scopus)

Abstract

A point-of-use (POU) water treatment system (WTS), comprised of a pressed activated carbon block filter followed by an ultraviolet (UV) light reactor, was evaluated for microbial disinfection efficacy following the general guidelines of the United States Environmental Protection Agency Guide Standard and Protocol for Testing Microbiological Water Purifiers. The POU WTS was challenged against bacterial, viral and protozoan waterborne pathogens including Vibrio cholerae, Shigella dysenteriae serotype 2, Escherichia coli 0157:H7, Salmonella typhi, hepatitis A virus strain HM 175, poliovirus type 1 strain Lsc2ab, simian rotavirus SA11, Cryptosporidium parvum oocysts, Giardia lamblia cysts and coliphage MS2. The POU WTS was tested for the removal/inactivation of each challenge organism in separate 16- to 20-day test periods under various conditions of water quality, at the system's maximum recommended flow rate and at 70% of the lamps normal UV intensity. For each organism tested, microbial challenges were conducted over the course of the test period at 0, 50, 100 and 150% of the system manufacturer's rated water treatment capacity. Each microbial challenge consisted of 30 L of influent water containing approximately 105 bacterial cfu/mL, 104 viral pfu/mL or 103 protozoan cysts/mL. Inffluent and effluent water samples were taken during the challenges and assayed for the particular pathogen and the percent reduction calculated. Effluent water samples were also taken and assayed for the possible presence of the pathogens following two 60-h stagnation periods. The POU WTS was found to effectively remove and/or inactivate greater than 99.9999% of the bacterial pathogens, greater than 99.99% of the viruses and greater than 99.9% of the protozoan cysts and oocysts tested to 150% of the water treatment capacity of the POU WTS. These findings suggest that a properly designed and operated POU WTS may be a practical approach to removing microbiological waterborne pathogens from drinking water.

Original languageEnglish (US)
Pages (from-to)574-582
Number of pages9
JournalWater Research
Volume31
Issue number3
DOIs
StatePublished - 1997

Fingerprint

Disinfection
Pathogens
Water treatment
disinfection
water treatment
pathogen
cyst
Viruses
Water
Effluents
virus
effluent
water
hepatitis
Salmonella
cholera
Environmental Protection Agency
Electric lamps
Potable water
Activated carbon

Keywords

  • Cryptosporidium parvum
  • Drinking water treatment
  • Escherichia coli
  • Giardia lamblia
  • Hepatitis A virus
  • Microbiological water purifier
  • Point-of-use water treatment system
  • Poliovirus type 1
  • Salmonella typhi
  • Shigella dysenteriae
  • Simian rotavirus SA11
  • Vibrio cholerae
  • Water disinfection

ASJC Scopus subject areas

  • Earth-Surface Processes

Cite this

The disinfection efficacy of a point-of-use water treatment system against bacterial, viral and protozoan waterborne pathogens. / Abbaszadegan, Morteza; Hasan, Michaela N.; Gerba, Charles P; Roessler, Peter F.; Wilson, Barth R.; Kuennen, Roy; Van Dellen, Eric.

In: Water Research, Vol. 31, No. 3, 1997, p. 574-582.

Research output: Contribution to journalArticle

Abbaszadegan, Morteza ; Hasan, Michaela N. ; Gerba, Charles P ; Roessler, Peter F. ; Wilson, Barth R. ; Kuennen, Roy ; Van Dellen, Eric. / The disinfection efficacy of a point-of-use water treatment system against bacterial, viral and protozoan waterborne pathogens. In: Water Research. 1997 ; Vol. 31, No. 3. pp. 574-582.
@article{94bae71bc7844ba288e31391e226a6d7,
title = "The disinfection efficacy of a point-of-use water treatment system against bacterial, viral and protozoan waterborne pathogens",
abstract = "A point-of-use (POU) water treatment system (WTS), comprised of a pressed activated carbon block filter followed by an ultraviolet (UV) light reactor, was evaluated for microbial disinfection efficacy following the general guidelines of the United States Environmental Protection Agency Guide Standard and Protocol for Testing Microbiological Water Purifiers. The POU WTS was challenged against bacterial, viral and protozoan waterborne pathogens including Vibrio cholerae, Shigella dysenteriae serotype 2, Escherichia coli 0157:H7, Salmonella typhi, hepatitis A virus strain HM 175, poliovirus type 1 strain Lsc2ab, simian rotavirus SA11, Cryptosporidium parvum oocysts, Giardia lamblia cysts and coliphage MS2. The POU WTS was tested for the removal/inactivation of each challenge organism in separate 16- to 20-day test periods under various conditions of water quality, at the system's maximum recommended flow rate and at 70{\%} of the lamps normal UV intensity. For each organism tested, microbial challenges were conducted over the course of the test period at 0, 50, 100 and 150{\%} of the system manufacturer's rated water treatment capacity. Each microbial challenge consisted of 30 L of influent water containing approximately 105 bacterial cfu/mL, 104 viral pfu/mL or 103 protozoan cysts/mL. Inffluent and effluent water samples were taken during the challenges and assayed for the particular pathogen and the percent reduction calculated. Effluent water samples were also taken and assayed for the possible presence of the pathogens following two 60-h stagnation periods. The POU WTS was found to effectively remove and/or inactivate greater than 99.9999{\%} of the bacterial pathogens, greater than 99.99{\%} of the viruses and greater than 99.9{\%} of the protozoan cysts and oocysts tested to 150{\%} of the water treatment capacity of the POU WTS. These findings suggest that a properly designed and operated POU WTS may be a practical approach to removing microbiological waterborne pathogens from drinking water.",
keywords = "Cryptosporidium parvum, Drinking water treatment, Escherichia coli, Giardia lamblia, Hepatitis A virus, Microbiological water purifier, Point-of-use water treatment system, Poliovirus type 1, Salmonella typhi, Shigella dysenteriae, Simian rotavirus SA11, Vibrio cholerae, Water disinfection",
author = "Morteza Abbaszadegan and Hasan, {Michaela N.} and Gerba, {Charles P} and Roessler, {Peter F.} and Wilson, {Barth R.} and Roy Kuennen and {Van Dellen}, Eric",
year = "1997",
doi = "10.1016/S0043-1354(96)00263-1",
language = "English (US)",
volume = "31",
pages = "574--582",
journal = "Water Research",
issn = "0043-1354",
publisher = "Elsevier Limited",
number = "3",

}

TY - JOUR

T1 - The disinfection efficacy of a point-of-use water treatment system against bacterial, viral and protozoan waterborne pathogens

AU - Abbaszadegan, Morteza

AU - Hasan, Michaela N.

AU - Gerba, Charles P

AU - Roessler, Peter F.

AU - Wilson, Barth R.

AU - Kuennen, Roy

AU - Van Dellen, Eric

PY - 1997

Y1 - 1997

N2 - A point-of-use (POU) water treatment system (WTS), comprised of a pressed activated carbon block filter followed by an ultraviolet (UV) light reactor, was evaluated for microbial disinfection efficacy following the general guidelines of the United States Environmental Protection Agency Guide Standard and Protocol for Testing Microbiological Water Purifiers. The POU WTS was challenged against bacterial, viral and protozoan waterborne pathogens including Vibrio cholerae, Shigella dysenteriae serotype 2, Escherichia coli 0157:H7, Salmonella typhi, hepatitis A virus strain HM 175, poliovirus type 1 strain Lsc2ab, simian rotavirus SA11, Cryptosporidium parvum oocysts, Giardia lamblia cysts and coliphage MS2. The POU WTS was tested for the removal/inactivation of each challenge organism in separate 16- to 20-day test periods under various conditions of water quality, at the system's maximum recommended flow rate and at 70% of the lamps normal UV intensity. For each organism tested, microbial challenges were conducted over the course of the test period at 0, 50, 100 and 150% of the system manufacturer's rated water treatment capacity. Each microbial challenge consisted of 30 L of influent water containing approximately 105 bacterial cfu/mL, 104 viral pfu/mL or 103 protozoan cysts/mL. Inffluent and effluent water samples were taken during the challenges and assayed for the particular pathogen and the percent reduction calculated. Effluent water samples were also taken and assayed for the possible presence of the pathogens following two 60-h stagnation periods. The POU WTS was found to effectively remove and/or inactivate greater than 99.9999% of the bacterial pathogens, greater than 99.99% of the viruses and greater than 99.9% of the protozoan cysts and oocysts tested to 150% of the water treatment capacity of the POU WTS. These findings suggest that a properly designed and operated POU WTS may be a practical approach to removing microbiological waterborne pathogens from drinking water.

AB - A point-of-use (POU) water treatment system (WTS), comprised of a pressed activated carbon block filter followed by an ultraviolet (UV) light reactor, was evaluated for microbial disinfection efficacy following the general guidelines of the United States Environmental Protection Agency Guide Standard and Protocol for Testing Microbiological Water Purifiers. The POU WTS was challenged against bacterial, viral and protozoan waterborne pathogens including Vibrio cholerae, Shigella dysenteriae serotype 2, Escherichia coli 0157:H7, Salmonella typhi, hepatitis A virus strain HM 175, poliovirus type 1 strain Lsc2ab, simian rotavirus SA11, Cryptosporidium parvum oocysts, Giardia lamblia cysts and coliphage MS2. The POU WTS was tested for the removal/inactivation of each challenge organism in separate 16- to 20-day test periods under various conditions of water quality, at the system's maximum recommended flow rate and at 70% of the lamps normal UV intensity. For each organism tested, microbial challenges were conducted over the course of the test period at 0, 50, 100 and 150% of the system manufacturer's rated water treatment capacity. Each microbial challenge consisted of 30 L of influent water containing approximately 105 bacterial cfu/mL, 104 viral pfu/mL or 103 protozoan cysts/mL. Inffluent and effluent water samples were taken during the challenges and assayed for the particular pathogen and the percent reduction calculated. Effluent water samples were also taken and assayed for the possible presence of the pathogens following two 60-h stagnation periods. The POU WTS was found to effectively remove and/or inactivate greater than 99.9999% of the bacterial pathogens, greater than 99.99% of the viruses and greater than 99.9% of the protozoan cysts and oocysts tested to 150% of the water treatment capacity of the POU WTS. These findings suggest that a properly designed and operated POU WTS may be a practical approach to removing microbiological waterborne pathogens from drinking water.

KW - Cryptosporidium parvum

KW - Drinking water treatment

KW - Escherichia coli

KW - Giardia lamblia

KW - Hepatitis A virus

KW - Microbiological water purifier

KW - Point-of-use water treatment system

KW - Poliovirus type 1

KW - Salmonella typhi

KW - Shigella dysenteriae

KW - Simian rotavirus SA11

KW - Vibrio cholerae

KW - Water disinfection

UR - http://www.scopus.com/inward/record.url?scp=0031081981&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031081981&partnerID=8YFLogxK

U2 - 10.1016/S0043-1354(96)00263-1

DO - 10.1016/S0043-1354(96)00263-1

M3 - Article

VL - 31

SP - 574

EP - 582

JO - Water Research

JF - Water Research

SN - 0043-1354

IS - 3

ER -