The effective depth of cylindrical ionization chambers in water for clinical proton beams

Amarjeet S. Bhullar, Christopher J Watchman

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

In this study, we have developed an explicit analytical model to compute the effective depth of cylindrical ionization chambers in water for clinical proton beams. We have compared our explicit analytical model with an existing series expansion model. We have calculated the shift of water equivalent depth for different cylindrical ionization chambers and have compared our results with the IAEA recommendations and series expansion model. We have developed a method to compute the elliptic integral in an explicit analytical form. Using this integral form, the shift of the water equivalent depth has been computed by accounting for individual contributions of the ionization chamber cavity, wall, central electrode and sleeve for proton energies ranging from 1.0 keV to 1.0 GeV for 34 commercially available ionization chambers. The comparison of an explicit analytical expression with a series expansion reveals that integrations calculated by the series expansion fail to converge to a precise value when the ratio of radii of cylindrical ionization chambers is greater than 0.5. For all the ion chambers selected in this study, our results vary at a maximum of 0.5 mm from the IAEA recommendations, whereas the maximum variation for the series expansion model is 1.5 mm. The findings of this study suggest that the developed analytical model is reliable for the calculation of the effective depth in water. Furthermore, the verification of these results with Monte Carlo calculation may suggest the need for a review of the standards for all commercial ionization chambers.

Original languageEnglish (US)
Pages (from-to)273-286
Number of pages14
JournalPhysics in Medicine and Biology
Volume57
Issue number1
DOIs
StatePublished - Jan 7 2012

Fingerprint

Protons
Water
Electrodes
Ions

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

The effective depth of cylindrical ionization chambers in water for clinical proton beams. / Bhullar, Amarjeet S.; Watchman, Christopher J.

In: Physics in Medicine and Biology, Vol. 57, No. 1, 07.01.2012, p. 273-286.

Research output: Contribution to journalArticle

@article{5ffd1be90c9b4d3793aebbd9682112bc,
title = "The effective depth of cylindrical ionization chambers in water for clinical proton beams",
abstract = "In this study, we have developed an explicit analytical model to compute the effective depth of cylindrical ionization chambers in water for clinical proton beams. We have compared our explicit analytical model with an existing series expansion model. We have calculated the shift of water equivalent depth for different cylindrical ionization chambers and have compared our results with the IAEA recommendations and series expansion model. We have developed a method to compute the elliptic integral in an explicit analytical form. Using this integral form, the shift of the water equivalent depth has been computed by accounting for individual contributions of the ionization chamber cavity, wall, central electrode and sleeve for proton energies ranging from 1.0 keV to 1.0 GeV for 34 commercially available ionization chambers. The comparison of an explicit analytical expression with a series expansion reveals that integrations calculated by the series expansion fail to converge to a precise value when the ratio of radii of cylindrical ionization chambers is greater than 0.5. For all the ion chambers selected in this study, our results vary at a maximum of 0.5 mm from the IAEA recommendations, whereas the maximum variation for the series expansion model is 1.5 mm. The findings of this study suggest that the developed analytical model is reliable for the calculation of the effective depth in water. Furthermore, the verification of these results with Monte Carlo calculation may suggest the need for a review of the standards for all commercial ionization chambers.",
author = "Bhullar, {Amarjeet S.} and Watchman, {Christopher J}",
year = "2012",
month = "1",
day = "7",
doi = "10.1088/0031-9155/57/1/273",
language = "English (US)",
volume = "57",
pages = "273--286",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - The effective depth of cylindrical ionization chambers in water for clinical proton beams

AU - Bhullar, Amarjeet S.

AU - Watchman, Christopher J

PY - 2012/1/7

Y1 - 2012/1/7

N2 - In this study, we have developed an explicit analytical model to compute the effective depth of cylindrical ionization chambers in water for clinical proton beams. We have compared our explicit analytical model with an existing series expansion model. We have calculated the shift of water equivalent depth for different cylindrical ionization chambers and have compared our results with the IAEA recommendations and series expansion model. We have developed a method to compute the elliptic integral in an explicit analytical form. Using this integral form, the shift of the water equivalent depth has been computed by accounting for individual contributions of the ionization chamber cavity, wall, central electrode and sleeve for proton energies ranging from 1.0 keV to 1.0 GeV for 34 commercially available ionization chambers. The comparison of an explicit analytical expression with a series expansion reveals that integrations calculated by the series expansion fail to converge to a precise value when the ratio of radii of cylindrical ionization chambers is greater than 0.5. For all the ion chambers selected in this study, our results vary at a maximum of 0.5 mm from the IAEA recommendations, whereas the maximum variation for the series expansion model is 1.5 mm. The findings of this study suggest that the developed analytical model is reliable for the calculation of the effective depth in water. Furthermore, the verification of these results with Monte Carlo calculation may suggest the need for a review of the standards for all commercial ionization chambers.

AB - In this study, we have developed an explicit analytical model to compute the effective depth of cylindrical ionization chambers in water for clinical proton beams. We have compared our explicit analytical model with an existing series expansion model. We have calculated the shift of water equivalent depth for different cylindrical ionization chambers and have compared our results with the IAEA recommendations and series expansion model. We have developed a method to compute the elliptic integral in an explicit analytical form. Using this integral form, the shift of the water equivalent depth has been computed by accounting for individual contributions of the ionization chamber cavity, wall, central electrode and sleeve for proton energies ranging from 1.0 keV to 1.0 GeV for 34 commercially available ionization chambers. The comparison of an explicit analytical expression with a series expansion reveals that integrations calculated by the series expansion fail to converge to a precise value when the ratio of radii of cylindrical ionization chambers is greater than 0.5. For all the ion chambers selected in this study, our results vary at a maximum of 0.5 mm from the IAEA recommendations, whereas the maximum variation for the series expansion model is 1.5 mm. The findings of this study suggest that the developed analytical model is reliable for the calculation of the effective depth in water. Furthermore, the verification of these results with Monte Carlo calculation may suggest the need for a review of the standards for all commercial ionization chambers.

UR - http://www.scopus.com/inward/record.url?scp=83455217394&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=83455217394&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/57/1/273

DO - 10.1088/0031-9155/57/1/273

M3 - Article

C2 - 22156108

AN - SCOPUS:83455217394

VL - 57

SP - 273

EP - 286

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 1

ER -