Intravenous fluid therapy is a mainstay in the treatment of trauma and hypovolemia. However, controversy exists as to its effective use by prehospital personnel. We reasoned that 12-gauge catheters, shown to have significantly greater fluid flow than 14- or 16-gauge catheters, might allow prehospital care providers to have a more significant role in patient resuscitation. This study was designed to see if 12-gauge intravenous catheters can successfully be placed and used in the prehospital care arena. During a six-month period, commercial peripheral 12-gauge catheter-over-needle intravenous units were placed in any hypovolemic or potentially hypovolemic patient in whom paramedics thought that rapid fluid therapy was, or might become, necessary. They experienced an overall success rate of 84 % and a success-per-attempt rate of 74 %. The catheters were placed under normal field conditions. Per preexisting protocols, departure from the scene and transport to the hospital were not delayed for any paramedic interventions, including starting intravenous lines. The 12-gauge catheters can be successfully used by paramedics, both to establish large bore intravenous access prior to arrival at the emergency department and to institute effective fluid therapy where time and circumstances allow.

Original languageEnglish (US)
Pages (from-to)173-176
Number of pages4
JournalJournal of Emergency Medicine
Volume8
Issue number2
DOIs
StatePublished - 1990

Fingerprint

Catheters
Allied Health Personnel
Hypovolemia
Fluid Therapy
Resuscitation
Needles
Hospital Emergency Service
Wounds and Injuries
Therapeutics

Keywords

  • fluid resuscitation
  • intravenous
  • prehospital

ASJC Scopus subject areas

  • Emergency Medicine

Cite this

The feasibility of 12-gauge intravenous catheter use in the prehospital setting. / Guisto, John A; Iserson, Kenneth V.

In: Journal of Emergency Medicine, Vol. 8, No. 2, 1990, p. 173-176.

Research output: Contribution to journalArticle

@article{d7391dd873d444fc816db7e660251186,
title = "The feasibility of 12-gauge intravenous catheter use in the prehospital setting",
abstract = "Intravenous fluid therapy is a mainstay in the treatment of trauma and hypovolemia. However, controversy exists as to its effective use by prehospital personnel. We reasoned that 12-gauge catheters, shown to have significantly greater fluid flow than 14- or 16-gauge catheters, might allow prehospital care providers to have a more significant role in patient resuscitation. This study was designed to see if 12-gauge intravenous catheters can successfully be placed and used in the prehospital care arena. During a six-month period, commercial peripheral 12-gauge catheter-over-needle intravenous units were placed in any hypovolemic or potentially hypovolemic patient in whom paramedics thought that rapid fluid therapy was, or might become, necessary. They experienced an overall success rate of 84 {\%} and a success-per-attempt rate of 74 {\%}. The catheters were placed under normal field conditions. Per preexisting protocols, departure from the scene and transport to the hospital were not delayed for any paramedic interventions, including starting intravenous lines. The 12-gauge catheters can be successfully used by paramedics, both to establish large bore intravenous access prior to arrival at the emergency department and to institute effective fluid therapy where time and circumstances allow.",
keywords = "fluid resuscitation, intravenous, prehospital",
author = "Guisto, {John A} and Iserson, {Kenneth V.}",
year = "1990",
doi = "10.1016/0736-4679(90)90228-N",
language = "English (US)",
volume = "8",
pages = "173--176",
journal = "Journal of Emergency Medicine",
issn = "0736-4679",
publisher = "Elsevier USA",
number = "2",

}

TY - JOUR

T1 - The feasibility of 12-gauge intravenous catheter use in the prehospital setting

AU - Guisto, John A

AU - Iserson, Kenneth V.

PY - 1990

Y1 - 1990

N2 - Intravenous fluid therapy is a mainstay in the treatment of trauma and hypovolemia. However, controversy exists as to its effective use by prehospital personnel. We reasoned that 12-gauge catheters, shown to have significantly greater fluid flow than 14- or 16-gauge catheters, might allow prehospital care providers to have a more significant role in patient resuscitation. This study was designed to see if 12-gauge intravenous catheters can successfully be placed and used in the prehospital care arena. During a six-month period, commercial peripheral 12-gauge catheter-over-needle intravenous units were placed in any hypovolemic or potentially hypovolemic patient in whom paramedics thought that rapid fluid therapy was, or might become, necessary. They experienced an overall success rate of 84 % and a success-per-attempt rate of 74 %. The catheters were placed under normal field conditions. Per preexisting protocols, departure from the scene and transport to the hospital were not delayed for any paramedic interventions, including starting intravenous lines. The 12-gauge catheters can be successfully used by paramedics, both to establish large bore intravenous access prior to arrival at the emergency department and to institute effective fluid therapy where time and circumstances allow.

AB - Intravenous fluid therapy is a mainstay in the treatment of trauma and hypovolemia. However, controversy exists as to its effective use by prehospital personnel. We reasoned that 12-gauge catheters, shown to have significantly greater fluid flow than 14- or 16-gauge catheters, might allow prehospital care providers to have a more significant role in patient resuscitation. This study was designed to see if 12-gauge intravenous catheters can successfully be placed and used in the prehospital care arena. During a six-month period, commercial peripheral 12-gauge catheter-over-needle intravenous units were placed in any hypovolemic or potentially hypovolemic patient in whom paramedics thought that rapid fluid therapy was, or might become, necessary. They experienced an overall success rate of 84 % and a success-per-attempt rate of 74 %. The catheters were placed under normal field conditions. Per preexisting protocols, departure from the scene and transport to the hospital were not delayed for any paramedic interventions, including starting intravenous lines. The 12-gauge catheters can be successfully used by paramedics, both to establish large bore intravenous access prior to arrival at the emergency department and to institute effective fluid therapy where time and circumstances allow.

KW - fluid resuscitation

KW - intravenous

KW - prehospital

UR - http://www.scopus.com/inward/record.url?scp=0025365212&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025365212&partnerID=8YFLogxK

U2 - 10.1016/0736-4679(90)90228-N

DO - 10.1016/0736-4679(90)90228-N

M3 - Article

VL - 8

SP - 173

EP - 176

JO - Journal of Emergency Medicine

JF - Journal of Emergency Medicine

SN - 0736-4679

IS - 2

ER -