The influence of groin sepsis on extraanatomic bypass patency in patients with prosthetic graft infection

Spence M. Taylor, Joseph L Mills, Roy M. Fujitani, Jacob G. Robison

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Twenty-seven vascular prosthetic graft infections in 25 patients were managed from 1981 through 1990 using the principles of extraanatomic bypass through uncontaminated fields and removal of the infected prosthesis. This experience included 18 aortic, three femoral-femoral, three femoral-popliteal, two axillofemoral grafts, and one popliteal endarterectomy patch. The predominant organism was Staphylococcus epidermidis (26%). Mean follow-up was 36 months. There was only one early and one late death, with two late amputations. Extraanatomic bypass grafts were placed in 21 of 25 patients including all 18 infected aortic grafts. Of these 21 patients, 11 (52%) experienced at least one extraanatomic bypass failure within 15 months, resulting directly in two major lower extremity amputations and two graft reinfections. Axillounifemoral bypass had a higher incidence of failure than axillobifemoral bypass (54% versus 29%). More importantly, however, extraanatomic graft failure was also associated with the presence of groin sepsis. The revision rate was 63% when the graft required circuitous tunneling to avoid groin sepsis, in contrast to a revision rate of only 17% when the graft could be anastomosed directly to the common femoral artery. Of extraanatomic bypass grafts that failed once, 63% had multiple failures. Graft removal and extraanatomic revascularization produced excellent overall results when not involving the groin. Late complications occurred more frequently when groin sepsis was present. These results suggest that, to reduce the incidence of late graft failure and amputation, more aggressive early direct reconstruction should be performed in lieu of atypical graft tunneling, especially if the extraanatomic graft has failed once and the causative organism is Staphylococcus epidermidis.

Original languageEnglish (US)
Pages (from-to)80-84
Number of pages5
JournalAnnals of Vascular Surgery
Volume6
Issue number1
DOIs
StatePublished - Jan 1992
Externally publishedYes

Fingerprint

Groin
Sepsis
Transplants
Infection
Thigh
Amputation
Staphylococcus epidermidis
Endarterectomy
Incidence
Femoral Artery
Prostheses and Implants
Blood Vessels
Lower Extremity

Keywords

  • Extraanatomic bypass
  • graft infection
  • graft removal
  • groin sepsis
  • peripheral vascular surgery

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Surgery

Cite this

The influence of groin sepsis on extraanatomic bypass patency in patients with prosthetic graft infection. / Taylor, Spence M.; Mills, Joseph L; Fujitani, Roy M.; Robison, Jacob G.

In: Annals of Vascular Surgery, Vol. 6, No. 1, 01.1992, p. 80-84.

Research output: Contribution to journalArticle

@article{f7e99991d3774778a338277685c0df8b,
title = "The influence of groin sepsis on extraanatomic bypass patency in patients with prosthetic graft infection",
abstract = "Twenty-seven vascular prosthetic graft infections in 25 patients were managed from 1981 through 1990 using the principles of extraanatomic bypass through uncontaminated fields and removal of the infected prosthesis. This experience included 18 aortic, three femoral-femoral, three femoral-popliteal, two axillofemoral grafts, and one popliteal endarterectomy patch. The predominant organism was Staphylococcus epidermidis (26{\%}). Mean follow-up was 36 months. There was only one early and one late death, with two late amputations. Extraanatomic bypass grafts were placed in 21 of 25 patients including all 18 infected aortic grafts. Of these 21 patients, 11 (52{\%}) experienced at least one extraanatomic bypass failure within 15 months, resulting directly in two major lower extremity amputations and two graft reinfections. Axillounifemoral bypass had a higher incidence of failure than axillobifemoral bypass (54{\%} versus 29{\%}). More importantly, however, extraanatomic graft failure was also associated with the presence of groin sepsis. The revision rate was 63{\%} when the graft required circuitous tunneling to avoid groin sepsis, in contrast to a revision rate of only 17{\%} when the graft could be anastomosed directly to the common femoral artery. Of extraanatomic bypass grafts that failed once, 63{\%} had multiple failures. Graft removal and extraanatomic revascularization produced excellent overall results when not involving the groin. Late complications occurred more frequently when groin sepsis was present. These results suggest that, to reduce the incidence of late graft failure and amputation, more aggressive early direct reconstruction should be performed in lieu of atypical graft tunneling, especially if the extraanatomic graft has failed once and the causative organism is Staphylococcus epidermidis.",
keywords = "Extraanatomic bypass, graft infection, graft removal, groin sepsis, peripheral vascular surgery",
author = "Taylor, {Spence M.} and Mills, {Joseph L} and Fujitani, {Roy M.} and Robison, {Jacob G.}",
year = "1992",
month = "1",
doi = "10.1007/BF02000673",
language = "English (US)",
volume = "6",
pages = "80--84",
journal = "Annals of Vascular Surgery",
issn = "0890-5096",
publisher = "Elsevier Inc.",
number = "1",

}

TY - JOUR

T1 - The influence of groin sepsis on extraanatomic bypass patency in patients with prosthetic graft infection

AU - Taylor, Spence M.

AU - Mills, Joseph L

AU - Fujitani, Roy M.

AU - Robison, Jacob G.

PY - 1992/1

Y1 - 1992/1

N2 - Twenty-seven vascular prosthetic graft infections in 25 patients were managed from 1981 through 1990 using the principles of extraanatomic bypass through uncontaminated fields and removal of the infected prosthesis. This experience included 18 aortic, three femoral-femoral, three femoral-popliteal, two axillofemoral grafts, and one popliteal endarterectomy patch. The predominant organism was Staphylococcus epidermidis (26%). Mean follow-up was 36 months. There was only one early and one late death, with two late amputations. Extraanatomic bypass grafts were placed in 21 of 25 patients including all 18 infected aortic grafts. Of these 21 patients, 11 (52%) experienced at least one extraanatomic bypass failure within 15 months, resulting directly in two major lower extremity amputations and two graft reinfections. Axillounifemoral bypass had a higher incidence of failure than axillobifemoral bypass (54% versus 29%). More importantly, however, extraanatomic graft failure was also associated with the presence of groin sepsis. The revision rate was 63% when the graft required circuitous tunneling to avoid groin sepsis, in contrast to a revision rate of only 17% when the graft could be anastomosed directly to the common femoral artery. Of extraanatomic bypass grafts that failed once, 63% had multiple failures. Graft removal and extraanatomic revascularization produced excellent overall results when not involving the groin. Late complications occurred more frequently when groin sepsis was present. These results suggest that, to reduce the incidence of late graft failure and amputation, more aggressive early direct reconstruction should be performed in lieu of atypical graft tunneling, especially if the extraanatomic graft has failed once and the causative organism is Staphylococcus epidermidis.

AB - Twenty-seven vascular prosthetic graft infections in 25 patients were managed from 1981 through 1990 using the principles of extraanatomic bypass through uncontaminated fields and removal of the infected prosthesis. This experience included 18 aortic, three femoral-femoral, three femoral-popliteal, two axillofemoral grafts, and one popliteal endarterectomy patch. The predominant organism was Staphylococcus epidermidis (26%). Mean follow-up was 36 months. There was only one early and one late death, with two late amputations. Extraanatomic bypass grafts were placed in 21 of 25 patients including all 18 infected aortic grafts. Of these 21 patients, 11 (52%) experienced at least one extraanatomic bypass failure within 15 months, resulting directly in two major lower extremity amputations and two graft reinfections. Axillounifemoral bypass had a higher incidence of failure than axillobifemoral bypass (54% versus 29%). More importantly, however, extraanatomic graft failure was also associated with the presence of groin sepsis. The revision rate was 63% when the graft required circuitous tunneling to avoid groin sepsis, in contrast to a revision rate of only 17% when the graft could be anastomosed directly to the common femoral artery. Of extraanatomic bypass grafts that failed once, 63% had multiple failures. Graft removal and extraanatomic revascularization produced excellent overall results when not involving the groin. Late complications occurred more frequently when groin sepsis was present. These results suggest that, to reduce the incidence of late graft failure and amputation, more aggressive early direct reconstruction should be performed in lieu of atypical graft tunneling, especially if the extraanatomic graft has failed once and the causative organism is Staphylococcus epidermidis.

KW - Extraanatomic bypass

KW - graft infection

KW - graft removal

KW - groin sepsis

KW - peripheral vascular surgery

UR - http://www.scopus.com/inward/record.url?scp=0026521267&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026521267&partnerID=8YFLogxK

U2 - 10.1007/BF02000673

DO - 10.1007/BF02000673

M3 - Article

C2 - 1532123

AN - SCOPUS:0026521267

VL - 6

SP - 80

EP - 84

JO - Annals of Vascular Surgery

JF - Annals of Vascular Surgery

SN - 0890-5096

IS - 1

ER -