The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea

Shahrokh Javaheri, Mark G. Goetting, Rami Khayat, Paul E. Wylie, James L. Goodwin, Sairam Parthasarathy

Research output: Contribution to journalArticle

38 Citations (Scopus)

Abstract

Introduction: This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). Study Design: A prospective, multicenter, randomized, controlled trial. Setting: Five sleep laboratories in the United States. Participants: Thirty-seven participants were included. Measurements and Results: All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. Conclusions: BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.

Original languageEnglish (US)
Pages (from-to)1693-1698
Number of pages6
JournalSleep
Volume34
Issue number12
DOIs
StatePublished - Dec 1 2011

Fingerprint

Central Sleep Apnea
Ventilation
Continuous Positive Airway Pressure
Sleep
Equipment and Supplies
Polysomnography
Apnea
Mechanical Ventilators
Respiration
Therapeutics
Social Adjustment
Sleep Apnea Syndromes
Randomized Controlled Trials
Pressure

Keywords

  • Auto EPAP
  • Bilevel positive pressure ventilation
  • Central sleep apnea
  • Pressure support
  • Servo-ventilation

ASJC Scopus subject areas

  • Physiology (medical)
  • Clinical Neurology

Cite this

The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea. / Javaheri, Shahrokh; Goetting, Mark G.; Khayat, Rami; Wylie, Paul E.; Goodwin, James L.; Parthasarathy, Sairam.

In: Sleep, Vol. 34, No. 12, 01.12.2011, p. 1693-1698.

Research output: Contribution to journalArticle

Javaheri, S, Goetting, MG, Khayat, R, Wylie, PE, Goodwin, JL & Parthasarathy, S 2011, 'The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea', Sleep, vol. 34, no. 12, pp. 1693-1698. https://doi.org/10.5665/sleep.1438
Javaheri, Shahrokh ; Goetting, Mark G. ; Khayat, Rami ; Wylie, Paul E. ; Goodwin, James L. ; Parthasarathy, Sairam. / The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea. In: Sleep. 2011 ; Vol. 34, No. 12. pp. 1693-1698.
@article{77aa00d827224e9187390c4827fdef17,
title = "The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea",
abstract = "Introduction: This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). Study Design: A prospective, multicenter, randomized, controlled trial. Setting: Five sleep laboratories in the United States. Participants: Thirty-seven participants were included. Measurements and Results: All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. Conclusions: BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.",
keywords = "Auto EPAP, Bilevel positive pressure ventilation, Central sleep apnea, Pressure support, Servo-ventilation",
author = "Shahrokh Javaheri and Goetting, {Mark G.} and Rami Khayat and Wylie, {Paul E.} and Goodwin, {James L.} and Sairam Parthasarathy",
year = "2011",
month = "12",
day = "1",
doi = "10.5665/sleep.1438",
language = "English (US)",
volume = "34",
pages = "1693--1698",
journal = "Sleep",
issn = "0161-8105",
publisher = "American Academy of Sleep Medicine",
number = "12",

}

TY - JOUR

T1 - The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea

AU - Javaheri, Shahrokh

AU - Goetting, Mark G.

AU - Khayat, Rami

AU - Wylie, Paul E.

AU - Goodwin, James L.

AU - Parthasarathy, Sairam

PY - 2011/12/1

Y1 - 2011/12/1

N2 - Introduction: This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). Study Design: A prospective, multicenter, randomized, controlled trial. Setting: Five sleep laboratories in the United States. Participants: Thirty-seven participants were included. Measurements and Results: All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. Conclusions: BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.

AB - Introduction: This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). Study Design: A prospective, multicenter, randomized, controlled trial. Setting: Five sleep laboratories in the United States. Participants: Thirty-seven participants were included. Measurements and Results: All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. Conclusions: BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.

KW - Auto EPAP

KW - Bilevel positive pressure ventilation

KW - Central sleep apnea

KW - Pressure support

KW - Servo-ventilation

UR - http://www.scopus.com/inward/record.url?scp=82555173037&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=82555173037&partnerID=8YFLogxK

U2 - 10.5665/sleep.1438

DO - 10.5665/sleep.1438

M3 - Article

VL - 34

SP - 1693

EP - 1698

JO - Sleep

JF - Sleep

SN - 0161-8105

IS - 12

ER -