Thin polymer etalon arrays for high-resolution photoacoustic imaging

Yang Hou, Sheng Wen Huang, Shai Ashkenazi, Russell S Witte, Matthew O'Donnell

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

Thin polymer etalons are demonstrated as high-frequency ultrasound sensors for three-dimensional (3-D) high-resolution photoacoustic imaging. The etalon, a Fabry-Perot optical resonator, consists of a thin polymer slab sandwiched between two gold layers. It is probed with a scanning continuous-wave (CW) laser for ultrasound array detection. Detection bandwidth of a 20-μm-diam array element exceeds 50 MHz, and the ultrasound sensitivity is comparable to polyvinylidene fluoride (PVDF) equivalents of similar size. In a typical photoacoustic imaging setup, a pulsed laser beam illuminates the imaging target, where optical energy is absorbed and acoustic waves are generated through the thermoelastic effect. An ultrasound detection array is formed by scanning the probing laser beam on the etalon surface in either a 1-D or a 2-D configuration, which produces 2-D or 3-D images, respectively. Axial and lateral resolutions have been demonstrated to be better than 20 μm. Detailed characterizations of the optical and acoustical properties of the etalon, as well as photoacoustic imaging results, suggest that thin polymer etalon arrays can be used as ultrasound detectors for 3-D high-resolution photoacoustic imaging applications.

Original languageEnglish (US)
Article number064033
JournalJournal of Biomedical Optics
Volume13
Issue number6
DOIs
StatePublished - 2008

Fingerprint

Photoacoustic effect
Polymers
Ultrasonics
Imaging techniques
high resolution
polymers
Laser beams
laser beams
etalons
Etalons
optical resonators
scanning
continuous wave lasers
Optical resonators
Scanning
vinylidene
Continuous wave lasers
fluorides
pulsed lasers
slabs

Keywords

  • Etalon
  • High-frequency ultrasound
  • High-resolution imaging
  • Optoacoustic detection
  • Photoacoustic imaging

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials
  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics

Cite this

Thin polymer etalon arrays for high-resolution photoacoustic imaging. / Hou, Yang; Huang, Sheng Wen; Ashkenazi, Shai; Witte, Russell S; O'Donnell, Matthew.

In: Journal of Biomedical Optics, Vol. 13, No. 6, 064033, 2008.

Research output: Contribution to journalArticle

Hou, Yang ; Huang, Sheng Wen ; Ashkenazi, Shai ; Witte, Russell S ; O'Donnell, Matthew. / Thin polymer etalon arrays for high-resolution photoacoustic imaging. In: Journal of Biomedical Optics. 2008 ; Vol. 13, No. 6.
@article{5d0765d4a47446b7bed8e3af59ac2aea,
title = "Thin polymer etalon arrays for high-resolution photoacoustic imaging",
abstract = "Thin polymer etalons are demonstrated as high-frequency ultrasound sensors for three-dimensional (3-D) high-resolution photoacoustic imaging. The etalon, a Fabry-Perot optical resonator, consists of a thin polymer slab sandwiched between two gold layers. It is probed with a scanning continuous-wave (CW) laser for ultrasound array detection. Detection bandwidth of a 20-μm-diam array element exceeds 50 MHz, and the ultrasound sensitivity is comparable to polyvinylidene fluoride (PVDF) equivalents of similar size. In a typical photoacoustic imaging setup, a pulsed laser beam illuminates the imaging target, where optical energy is absorbed and acoustic waves are generated through the thermoelastic effect. An ultrasound detection array is formed by scanning the probing laser beam on the etalon surface in either a 1-D or a 2-D configuration, which produces 2-D or 3-D images, respectively. Axial and lateral resolutions have been demonstrated to be better than 20 μm. Detailed characterizations of the optical and acoustical properties of the etalon, as well as photoacoustic imaging results, suggest that thin polymer etalon arrays can be used as ultrasound detectors for 3-D high-resolution photoacoustic imaging applications.",
keywords = "Etalon, High-frequency ultrasound, High-resolution imaging, Optoacoustic detection, Photoacoustic imaging",
author = "Yang Hou and Huang, {Sheng Wen} and Shai Ashkenazi and Witte, {Russell S} and Matthew O'Donnell",
year = "2008",
doi = "10.1117/1.3042260",
language = "English (US)",
volume = "13",
journal = "Journal of Biomedical Optics",
issn = "1083-3668",
publisher = "SPIE",
number = "6",

}

TY - JOUR

T1 - Thin polymer etalon arrays for high-resolution photoacoustic imaging

AU - Hou, Yang

AU - Huang, Sheng Wen

AU - Ashkenazi, Shai

AU - Witte, Russell S

AU - O'Donnell, Matthew

PY - 2008

Y1 - 2008

N2 - Thin polymer etalons are demonstrated as high-frequency ultrasound sensors for three-dimensional (3-D) high-resolution photoacoustic imaging. The etalon, a Fabry-Perot optical resonator, consists of a thin polymer slab sandwiched between two gold layers. It is probed with a scanning continuous-wave (CW) laser for ultrasound array detection. Detection bandwidth of a 20-μm-diam array element exceeds 50 MHz, and the ultrasound sensitivity is comparable to polyvinylidene fluoride (PVDF) equivalents of similar size. In a typical photoacoustic imaging setup, a pulsed laser beam illuminates the imaging target, where optical energy is absorbed and acoustic waves are generated through the thermoelastic effect. An ultrasound detection array is formed by scanning the probing laser beam on the etalon surface in either a 1-D or a 2-D configuration, which produces 2-D or 3-D images, respectively. Axial and lateral resolutions have been demonstrated to be better than 20 μm. Detailed characterizations of the optical and acoustical properties of the etalon, as well as photoacoustic imaging results, suggest that thin polymer etalon arrays can be used as ultrasound detectors for 3-D high-resolution photoacoustic imaging applications.

AB - Thin polymer etalons are demonstrated as high-frequency ultrasound sensors for three-dimensional (3-D) high-resolution photoacoustic imaging. The etalon, a Fabry-Perot optical resonator, consists of a thin polymer slab sandwiched between two gold layers. It is probed with a scanning continuous-wave (CW) laser for ultrasound array detection. Detection bandwidth of a 20-μm-diam array element exceeds 50 MHz, and the ultrasound sensitivity is comparable to polyvinylidene fluoride (PVDF) equivalents of similar size. In a typical photoacoustic imaging setup, a pulsed laser beam illuminates the imaging target, where optical energy is absorbed and acoustic waves are generated through the thermoelastic effect. An ultrasound detection array is formed by scanning the probing laser beam on the etalon surface in either a 1-D or a 2-D configuration, which produces 2-D or 3-D images, respectively. Axial and lateral resolutions have been demonstrated to be better than 20 μm. Detailed characterizations of the optical and acoustical properties of the etalon, as well as photoacoustic imaging results, suggest that thin polymer etalon arrays can be used as ultrasound detectors for 3-D high-resolution photoacoustic imaging applications.

KW - Etalon

KW - High-frequency ultrasound

KW - High-resolution imaging

KW - Optoacoustic detection

KW - Photoacoustic imaging

UR - http://www.scopus.com/inward/record.url?scp=62449323773&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=62449323773&partnerID=8YFLogxK

U2 - 10.1117/1.3042260

DO - 10.1117/1.3042260

M3 - Article

C2 - 19123679

AN - SCOPUS:62449323773

VL - 13

JO - Journal of Biomedical Optics

JF - Journal of Biomedical Optics

SN - 1083-3668

IS - 6

M1 - 064033

ER -