TY - JOUR
T1 - TRACE ELEMENT DETERMINATIONS FOR USGS BASALT BHVO‐1 AND NIST STANDARD REFERENCE MATERIALS 278, 688 AND 694 BY INDUCTIVELY COUPLED PLASMA‐MASS SPECTROMETRY
AU - HOLLOCHER, Kurt
AU - FAKHRY, Ahmed
AU - Ruiz, Joaquin
PY - 1995
Y1 - 1995
N2 - Results are presented for 26 to 30 trace elements determined in four rock reference materials of geochemical interest: USGS Basalt BHVO‐1, Rhyolite Obsidian NIST 278, Basalt NIST688, and Phosphate Rock NIST694. Determinations were made by inductively coupled plasma mass spectrometry (ICP‐MS). Good agreement was obtained among solution standard comparison and standard addition analytical techniques, and among samples prepared with different dissolution methods. Generally good agreement was obtained between determined trace element values and values reported in the literature.
AB - Results are presented for 26 to 30 trace elements determined in four rock reference materials of geochemical interest: USGS Basalt BHVO‐1, Rhyolite Obsidian NIST 278, Basalt NIST688, and Phosphate Rock NIST694. Determinations were made by inductively coupled plasma mass spectrometry (ICP‐MS). Good agreement was obtained among solution standard comparison and standard addition analytical techniques, and among samples prepared with different dissolution methods. Generally good agreement was obtained between determined trace element values and values reported in the literature.
UR - http://www.scopus.com/inward/record.url?scp=84987572854&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84987572854&partnerID=8YFLogxK
U2 - 10.1111/j.1751-908X.1995.tb00150.x
DO - 10.1111/j.1751-908X.1995.tb00150.x
M3 - Article
AN - SCOPUS:84987572854
VL - 19
SP - 35
EP - 40
JO - Geostandards and Geoanalytical Research
JF - Geostandards and Geoanalytical Research
SN - 1639-4488
IS - 1
ER -