Abstract

The goal of single photon emission computerized tomography is to map out a three-dimensional distribution of a radionuclide that is concentrated in a structure of interest. There are a number of imaging modalities that achieve this goal with varying degrees of success. In this study, computer simulation is used to explore a novel imaging modality, orthogonal-view coded-aperture imaging. Furthermore, a comparison is made between two reconstruction algorithms, one being an iterative back-projection algorithm and the other a Monte Carlo algorithm. Finally, evidence is presented suggesting that a deficiency in the projection data due to multiplexing is less disturbing than that due to limited angular range.

Original languageEnglish (US)
Pages (from-to)700-705
Number of pages6
JournalJournal of Nuclear Medicine
Volume25
Issue number6
StatePublished - 1984

Fingerprint

Single-Photon Emission-Computed Tomography
Radioisotopes
Computer Simulation

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Two algorithms for use with an orthogonal-view coded-aperture system. / Paxman, R. G.; Smith, W. E.; Barrett, Harrison H.

In: Journal of Nuclear Medicine, Vol. 25, No. 6, 1984, p. 700-705.

Research output: Contribution to journalArticle

@article{8c8253b982524f2b8dcce79121fb341e,
title = "Two algorithms for use with an orthogonal-view coded-aperture system",
abstract = "The goal of single photon emission computerized tomography is to map out a three-dimensional distribution of a radionuclide that is concentrated in a structure of interest. There are a number of imaging modalities that achieve this goal with varying degrees of success. In this study, computer simulation is used to explore a novel imaging modality, orthogonal-view coded-aperture imaging. Furthermore, a comparison is made between two reconstruction algorithms, one being an iterative back-projection algorithm and the other a Monte Carlo algorithm. Finally, evidence is presented suggesting that a deficiency in the projection data due to multiplexing is less disturbing than that due to limited angular range.",
author = "Paxman, {R. G.} and Smith, {W. E.} and Barrett, {Harrison H}",
year = "1984",
language = "English (US)",
volume = "25",
pages = "700--705",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "6",

}

TY - JOUR

T1 - Two algorithms for use with an orthogonal-view coded-aperture system

AU - Paxman, R. G.

AU - Smith, W. E.

AU - Barrett, Harrison H

PY - 1984

Y1 - 1984

N2 - The goal of single photon emission computerized tomography is to map out a three-dimensional distribution of a radionuclide that is concentrated in a structure of interest. There are a number of imaging modalities that achieve this goal with varying degrees of success. In this study, computer simulation is used to explore a novel imaging modality, orthogonal-view coded-aperture imaging. Furthermore, a comparison is made between two reconstruction algorithms, one being an iterative back-projection algorithm and the other a Monte Carlo algorithm. Finally, evidence is presented suggesting that a deficiency in the projection data due to multiplexing is less disturbing than that due to limited angular range.

AB - The goal of single photon emission computerized tomography is to map out a three-dimensional distribution of a radionuclide that is concentrated in a structure of interest. There are a number of imaging modalities that achieve this goal with varying degrees of success. In this study, computer simulation is used to explore a novel imaging modality, orthogonal-view coded-aperture imaging. Furthermore, a comparison is made between two reconstruction algorithms, one being an iterative back-projection algorithm and the other a Monte Carlo algorithm. Finally, evidence is presented suggesting that a deficiency in the projection data due to multiplexing is less disturbing than that due to limited angular range.

UR - http://www.scopus.com/inward/record.url?scp=0021234919&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021234919&partnerID=8YFLogxK

M3 - Article

VL - 25

SP - 700

EP - 705

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 6

ER -