Abstract

Because of discrepancy in reports concerning the rate of uptake of nitrous oxide by man, it seemed desirable to measure this factor when automatic control of concentrations and rapid computer measurement of breath to breath uptake became available. Six subjects inhaled 25 per cent nitrous oxide for two hours. Total uptake and alveolar uptake were determined. The total inhaled uptake, adjusted for a 70 kg subject inhaling 75 per cent nitrous oxide, corresponded well with an absorption of about 1000 ml the first minute. After a wash-in period of less than four minutes, the alveolar uptake, which at that time and subsequently equaled the total uptake, decreased approximately according to the square root of time in minutes. Considerable variation appeared between individuals, but each course approximated the same type of decrease. Absorption continued to occur during the two hour period of observation.

Original languageEnglish (US)
Pages (from-to)424-427
Number of pages4
JournalCanadian Anaesthetists' Society Journal
Volume29
Issue number5
DOIs
StatePublished - Sep 1982
Externally publishedYes

Fingerprint

Nitrous Oxide
Inhalation
Observation

Keywords

  • Anaesthetics
  • Gases
  • nitrous oxide
  • uptake

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Uptake of nitrous oxide by man. / Virtue, Robert; Sherrill, Duane L; Swanson, George D.

In: Canadian Anaesthetists' Society Journal, Vol. 29, No. 5, 09.1982, p. 424-427.

Research output: Contribution to journalArticle

Virtue, Robert ; Sherrill, Duane L ; Swanson, George D. / Uptake of nitrous oxide by man. In: Canadian Anaesthetists' Society Journal. 1982 ; Vol. 29, No. 5. pp. 424-427.
@article{706f83fa116147ff80eed4e087220687,
title = "Uptake of nitrous oxide by man",
abstract = "Because of discrepancy in reports concerning the rate of uptake of nitrous oxide by man, it seemed desirable to measure this factor when automatic control of concentrations and rapid computer measurement of breath to breath uptake became available. Six subjects inhaled 25 per cent nitrous oxide for two hours. Total uptake and alveolar uptake were determined. The total inhaled uptake, adjusted for a 70 kg subject inhaling 75 per cent nitrous oxide, corresponded well with an absorption of about 1000 ml the first minute. After a wash-in period of less than four minutes, the alveolar uptake, which at that time and subsequently equaled the total uptake, decreased approximately according to the square root of time in minutes. Considerable variation appeared between individuals, but each course approximated the same type of decrease. Absorption continued to occur during the two hour period of observation.",
keywords = "Anaesthetics, Gases, nitrous oxide, uptake",
author = "Robert Virtue and Sherrill, {Duane L} and Swanson, {George D.}",
year = "1982",
month = "9",
doi = "10.1007/BF03009403",
language = "English (US)",
volume = "29",
pages = "424--427",
journal = "Canadian Anaesthetists Society Journal",
issn = "0832-610X",
publisher = "Canadian Anaesthetists Society",
number = "5",

}

TY - JOUR

T1 - Uptake of nitrous oxide by man

AU - Virtue, Robert

AU - Sherrill, Duane L

AU - Swanson, George D.

PY - 1982/9

Y1 - 1982/9

N2 - Because of discrepancy in reports concerning the rate of uptake of nitrous oxide by man, it seemed desirable to measure this factor when automatic control of concentrations and rapid computer measurement of breath to breath uptake became available. Six subjects inhaled 25 per cent nitrous oxide for two hours. Total uptake and alveolar uptake were determined. The total inhaled uptake, adjusted for a 70 kg subject inhaling 75 per cent nitrous oxide, corresponded well with an absorption of about 1000 ml the first minute. After a wash-in period of less than four minutes, the alveolar uptake, which at that time and subsequently equaled the total uptake, decreased approximately according to the square root of time in minutes. Considerable variation appeared between individuals, but each course approximated the same type of decrease. Absorption continued to occur during the two hour period of observation.

AB - Because of discrepancy in reports concerning the rate of uptake of nitrous oxide by man, it seemed desirable to measure this factor when automatic control of concentrations and rapid computer measurement of breath to breath uptake became available. Six subjects inhaled 25 per cent nitrous oxide for two hours. Total uptake and alveolar uptake were determined. The total inhaled uptake, adjusted for a 70 kg subject inhaling 75 per cent nitrous oxide, corresponded well with an absorption of about 1000 ml the first minute. After a wash-in period of less than four minutes, the alveolar uptake, which at that time and subsequently equaled the total uptake, decreased approximately according to the square root of time in minutes. Considerable variation appeared between individuals, but each course approximated the same type of decrease. Absorption continued to occur during the two hour period of observation.

KW - Anaesthetics

KW - Gases

KW - nitrous oxide

KW - uptake

UR - http://www.scopus.com/inward/record.url?scp=0019976320&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019976320&partnerID=8YFLogxK

U2 - 10.1007/BF03009403

DO - 10.1007/BF03009403

M3 - Article

C2 - 7127175

AN - SCOPUS:0019976320

VL - 29

SP - 424

EP - 427

JO - Canadian Anaesthetists Society Journal

JF - Canadian Anaesthetists Society Journal

SN - 0832-610X

IS - 5

ER -