Use of a cerebral angiographic catheter facilitates crossing the pulmonary valve in neonates with critical or severe pulmonary valve stenosis

Scott E Klewer, Rolando Zamora

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

In summary, we have determined that a pediatric cerebral catheter promotes successful crossing of the pulmonary valve, decreases overall procedural time, and may increase the safety of balloon valvuloplasty in neonates with pulmonary stenosis.

Original languageEnglish (US)
Pages (from-to)1245-1247
Number of pages3
JournalThe American journal of cardiology
Volume80
Issue number9
DOIs
StatePublished - Nov 1 1997
Externally publishedYes

Fingerprint

Balloon Valvuloplasty
Pulmonary Valve
Pulmonary Valve Stenosis
Catheters
Pediatrics
Safety

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

@article{ee38edf7980240f7be7fa42512fb0d5c,
title = "Use of a cerebral angiographic catheter facilitates crossing the pulmonary valve in neonates with critical or severe pulmonary valve stenosis",
abstract = "In summary, we have determined that a pediatric cerebral catheter promotes successful crossing of the pulmonary valve, decreases overall procedural time, and may increase the safety of balloon valvuloplasty in neonates with pulmonary stenosis.",
author = "Klewer, {Scott E} and Rolando Zamora",
year = "1997",
month = "11",
day = "1",
doi = "10.1016/S0002-9149(97)00654-1",
language = "English (US)",
volume = "80",
pages = "1245--1247",
journal = "American Journal of Cardiology",
issn = "0002-9149",
publisher = "Elsevier Inc.",
number = "9",

}

TY - JOUR

T1 - Use of a cerebral angiographic catheter facilitates crossing the pulmonary valve in neonates with critical or severe pulmonary valve stenosis

AU - Klewer, Scott E

AU - Zamora, Rolando

PY - 1997/11/1

Y1 - 1997/11/1

N2 - In summary, we have determined that a pediatric cerebral catheter promotes successful crossing of the pulmonary valve, decreases overall procedural time, and may increase the safety of balloon valvuloplasty in neonates with pulmonary stenosis.

AB - In summary, we have determined that a pediatric cerebral catheter promotes successful crossing of the pulmonary valve, decreases overall procedural time, and may increase the safety of balloon valvuloplasty in neonates with pulmonary stenosis.

UR - http://www.scopus.com/inward/record.url?scp=0030717471&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030717471&partnerID=8YFLogxK

U2 - 10.1016/S0002-9149(97)00654-1

DO - 10.1016/S0002-9149(97)00654-1

M3 - Article

C2 - 9359566

AN - SCOPUS:0030717471

VL - 80

SP - 1245

EP - 1247

JO - American Journal of Cardiology

JF - American Journal of Cardiology

SN - 0002-9149

IS - 9

ER -