Validation of conductance catheter system for quantification of murine pressure-volume loops

Bo Yang, Douglas F Larson, Julie Beischel, Ryan Kelley, Jiaqi Shi, Ronald R Watson

Research output: Contribution to journalArticle

42 Citations (Scopus)

Abstract

The purpose of this study was to define the validation methods and outcomes of a conductance catheter system specifically for in vivo murine cardiac hemodynamic analysis. To express the relationship between conductance and blood volumes, we used an in vitro model to derive a volume-conductance line. The volume-conductance line was used to compute raw volume from the modified conductance signals. The parallel volume was calibrated with hypertonic (15%) saline injected from extrajugular vein. The ventricular volume was computed by raw volume minus parallel volume. The accuracy of conductance volumetric measurements was validated with a static in situ infusion of calibrated volumes of whole blood injected into arrested left ventricles. In vivo dynamic measurements were performed with 24 C57B1/6 mice, 6 months old; for comparison of established values. The in situ model showed that after calibration, the experimental coefficient, α, was equal to 1 and the measured volume by conductance catheter was equal to the true volume of the left ventricle (y = 0.982× + 0.513, p < .0001). For the in vivo models, the end-diastolic volumes and the stroke volumes and cardiac output determined with the conductance catheter system were 17.3 ± 1.0 μL, 10.6 ± 0.9 μL, and 6.0 ± 0.5 mL/min, respectively. We validated the relationship between measured volume by conductance catheter and the true volume and demonstrated the accuracy of the volume-conductance line for conversion of conductance to volume.

Original languageEnglish (US)
Pages (from-to)341-355
Number of pages15
JournalJournal of Investigative Surgery
Volume14
Issue number6
DOIs
StatePublished - 2001

Fingerprint

Catheters
Pressure
Blood Volume
Heart Ventricles
Cardiac Output
Stroke Volume
Calibration
Veins
Hemodynamics

Keywords

  • Conductance
  • ESPVR
  • Hemodynamics
  • Mouse
  • PRSW
  • Ventricular function
  • Ventricular mechanics

ASJC Scopus subject areas

  • Surgery

Cite this

Validation of conductance catheter system for quantification of murine pressure-volume loops. / Yang, Bo; Larson, Douglas F; Beischel, Julie; Kelley, Ryan; Shi, Jiaqi; Watson, Ronald R.

In: Journal of Investigative Surgery, Vol. 14, No. 6, 2001, p. 341-355.

Research output: Contribution to journalArticle

@article{ade5a5d5119149d49cb45fffdd3fa696,
title = "Validation of conductance catheter system for quantification of murine pressure-volume loops",
abstract = "The purpose of this study was to define the validation methods and outcomes of a conductance catheter system specifically for in vivo murine cardiac hemodynamic analysis. To express the relationship between conductance and blood volumes, we used an in vitro model to derive a volume-conductance line. The volume-conductance line was used to compute raw volume from the modified conductance signals. The parallel volume was calibrated with hypertonic (15{\%}) saline injected from extrajugular vein. The ventricular volume was computed by raw volume minus parallel volume. The accuracy of conductance volumetric measurements was validated with a static in situ infusion of calibrated volumes of whole blood injected into arrested left ventricles. In vivo dynamic measurements were performed with 24 C57B1/6 mice, 6 months old; for comparison of established values. The in situ model showed that after calibration, the experimental coefficient, α, was equal to 1 and the measured volume by conductance catheter was equal to the true volume of the left ventricle (y = 0.982× + 0.513, p < .0001). For the in vivo models, the end-diastolic volumes and the stroke volumes and cardiac output determined with the conductance catheter system were 17.3 ± 1.0 μL, 10.6 ± 0.9 μL, and 6.0 ± 0.5 mL/min, respectively. We validated the relationship between measured volume by conductance catheter and the true volume and demonstrated the accuracy of the volume-conductance line for conversion of conductance to volume.",
keywords = "Conductance, ESPVR, Hemodynamics, Mouse, PRSW, Ventricular function, Ventricular mechanics",
author = "Bo Yang and Larson, {Douglas F} and Julie Beischel and Ryan Kelley and Jiaqi Shi and Watson, {Ronald R}",
year = "2001",
doi = "10.1080/089419301753435710",
language = "English (US)",
volume = "14",
pages = "341--355",
journal = "Journal of Investigative Surgery",
issn = "0894-1939",
publisher = "Informa Healthcare",
number = "6",

}

TY - JOUR

T1 - Validation of conductance catheter system for quantification of murine pressure-volume loops

AU - Yang, Bo

AU - Larson, Douglas F

AU - Beischel, Julie

AU - Kelley, Ryan

AU - Shi, Jiaqi

AU - Watson, Ronald R

PY - 2001

Y1 - 2001

N2 - The purpose of this study was to define the validation methods and outcomes of a conductance catheter system specifically for in vivo murine cardiac hemodynamic analysis. To express the relationship between conductance and blood volumes, we used an in vitro model to derive a volume-conductance line. The volume-conductance line was used to compute raw volume from the modified conductance signals. The parallel volume was calibrated with hypertonic (15%) saline injected from extrajugular vein. The ventricular volume was computed by raw volume minus parallel volume. The accuracy of conductance volumetric measurements was validated with a static in situ infusion of calibrated volumes of whole blood injected into arrested left ventricles. In vivo dynamic measurements were performed with 24 C57B1/6 mice, 6 months old; for comparison of established values. The in situ model showed that after calibration, the experimental coefficient, α, was equal to 1 and the measured volume by conductance catheter was equal to the true volume of the left ventricle (y = 0.982× + 0.513, p < .0001). For the in vivo models, the end-diastolic volumes and the stroke volumes and cardiac output determined with the conductance catheter system were 17.3 ± 1.0 μL, 10.6 ± 0.9 μL, and 6.0 ± 0.5 mL/min, respectively. We validated the relationship between measured volume by conductance catheter and the true volume and demonstrated the accuracy of the volume-conductance line for conversion of conductance to volume.

AB - The purpose of this study was to define the validation methods and outcomes of a conductance catheter system specifically for in vivo murine cardiac hemodynamic analysis. To express the relationship between conductance and blood volumes, we used an in vitro model to derive a volume-conductance line. The volume-conductance line was used to compute raw volume from the modified conductance signals. The parallel volume was calibrated with hypertonic (15%) saline injected from extrajugular vein. The ventricular volume was computed by raw volume minus parallel volume. The accuracy of conductance volumetric measurements was validated with a static in situ infusion of calibrated volumes of whole blood injected into arrested left ventricles. In vivo dynamic measurements were performed with 24 C57B1/6 mice, 6 months old; for comparison of established values. The in situ model showed that after calibration, the experimental coefficient, α, was equal to 1 and the measured volume by conductance catheter was equal to the true volume of the left ventricle (y = 0.982× + 0.513, p < .0001). For the in vivo models, the end-diastolic volumes and the stroke volumes and cardiac output determined with the conductance catheter system were 17.3 ± 1.0 μL, 10.6 ± 0.9 μL, and 6.0 ± 0.5 mL/min, respectively. We validated the relationship between measured volume by conductance catheter and the true volume and demonstrated the accuracy of the volume-conductance line for conversion of conductance to volume.

KW - Conductance

KW - ESPVR

KW - Hemodynamics

KW - Mouse

KW - PRSW

KW - Ventricular function

KW - Ventricular mechanics

UR - http://www.scopus.com/inward/record.url?scp=0035570190&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035570190&partnerID=8YFLogxK

U2 - 10.1080/089419301753435710

DO - 10.1080/089419301753435710

M3 - Article

C2 - 11905502

AN - SCOPUS:0035570190

VL - 14

SP - 341

EP - 355

JO - Journal of Investigative Surgery

JF - Journal of Investigative Surgery

SN - 0894-1939

IS - 6

ER -