Variations of isotopic discrimination in secondary ion mass spectrometry

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Isotopic discrimination in a Cameca IMS-3f ion microprobe has been measured as a function of mass, and of primary and secondary ion energy. Discrimination factors were determined for a series of elements (Pb, Mo, Cu, Ni, Cr, Ti and Si) as metallic targets, using an O2+ primary beam. The results show a trend of isotope ratio, and by inference of the fraction of atoms ionized, proportional to M-0.75. Energy-range selection was used to identify a dependence of the measured isotope ratios on the secondary ion energy, favoring the lighter isotopes, ions of lower energy being more fractionated. A small variation with primary ion energy from 0.5 to 13 ke V was also observed fractionation increasing with decreasing primary beam energy. These effects, together with those due to possible instrumental discrimination, must be taken into account for a complete understanding of isotopic measurements obtained by secondary ion mass spectrometry.

Original languageEnglish (US)
Pages (from-to)135-141
Number of pages7
JournalInternational Journal of Mass Spectrometry and Ion Physics
Volume41
Issue number3
DOIs
StatePublished - 1982
Externally publishedYes

Fingerprint

Secondary ion mass spectrometry
secondary ion mass spectrometry
discrimination
Ions
Isotopes
isotope ratios
ions
energy
International Magnetospheric Study
Fractionation
inference
fractionation
isotopes
Atoms
trends
atoms

Cite this

@article{dcc38ab1429c42f39d9d712a67f53cec,
title = "Variations of isotopic discrimination in secondary ion mass spectrometry",
abstract = "Isotopic discrimination in a Cameca IMS-3f ion microprobe has been measured as a function of mass, and of primary and secondary ion energy. Discrimination factors were determined for a series of elements (Pb, Mo, Cu, Ni, Cr, Ti and Si) as metallic targets, using an O2+ primary beam. The results show a trend of isotope ratio, and by inference of the fraction of atoms ionized, proportional to M-0.75. Energy-range selection was used to identify a dependence of the measured isotope ratios on the secondary ion energy, favoring the lighter isotopes, ions of lower energy being more fractionated. A small variation with primary ion energy from 0.5 to 13 ke V was also observed fractionation increasing with decreasing primary beam energy. These effects, together with those due to possible instrumental discrimination, must be taken into account for a complete understanding of isotopic measurements obtained by secondary ion mass spectrometry.",
author = "Jull, {A.J. Timothy}",
year = "1982",
doi = "10.1016/0020-7381(82)85030-4",
language = "English (US)",
volume = "41",
pages = "135--141",
journal = "International Journal of Mass Spectrometry",
issn = "1387-3806",
publisher = "Elsevier",
number = "3",

}

TY - JOUR

T1 - Variations of isotopic discrimination in secondary ion mass spectrometry

AU - Jull, A.J. Timothy

PY - 1982

Y1 - 1982

N2 - Isotopic discrimination in a Cameca IMS-3f ion microprobe has been measured as a function of mass, and of primary and secondary ion energy. Discrimination factors were determined for a series of elements (Pb, Mo, Cu, Ni, Cr, Ti and Si) as metallic targets, using an O2+ primary beam. The results show a trend of isotope ratio, and by inference of the fraction of atoms ionized, proportional to M-0.75. Energy-range selection was used to identify a dependence of the measured isotope ratios on the secondary ion energy, favoring the lighter isotopes, ions of lower energy being more fractionated. A small variation with primary ion energy from 0.5 to 13 ke V was also observed fractionation increasing with decreasing primary beam energy. These effects, together with those due to possible instrumental discrimination, must be taken into account for a complete understanding of isotopic measurements obtained by secondary ion mass spectrometry.

AB - Isotopic discrimination in a Cameca IMS-3f ion microprobe has been measured as a function of mass, and of primary and secondary ion energy. Discrimination factors were determined for a series of elements (Pb, Mo, Cu, Ni, Cr, Ti and Si) as metallic targets, using an O2+ primary beam. The results show a trend of isotope ratio, and by inference of the fraction of atoms ionized, proportional to M-0.75. Energy-range selection was used to identify a dependence of the measured isotope ratios on the secondary ion energy, favoring the lighter isotopes, ions of lower energy being more fractionated. A small variation with primary ion energy from 0.5 to 13 ke V was also observed fractionation increasing with decreasing primary beam energy. These effects, together with those due to possible instrumental discrimination, must be taken into account for a complete understanding of isotopic measurements obtained by secondary ion mass spectrometry.

UR - http://www.scopus.com/inward/record.url?scp=30844435462&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=30844435462&partnerID=8YFLogxK

U2 - 10.1016/0020-7381(82)85030-4

DO - 10.1016/0020-7381(82)85030-4

M3 - Article

VL - 41

SP - 135

EP - 141

JO - International Journal of Mass Spectrometry

JF - International Journal of Mass Spectrometry

SN - 1387-3806

IS - 3

ER -