Wall stress reduction in abdominal aortic aneurysms as a result of polymeric endoaortic paving

John H. Ashton, Avinash Ayyalasomayajula, Bruce R. Simon, Jonathan P Vande Geest

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Polymeric endoaortic paving (PEAP) may improve endovascular repair of abdominal aortic aneurysms (AAA) since it has the potential to treat patients with complex AAA geometries while reducing the incidence of migration and endoleak. Polycaprolactone (PCL)/polyurethane (PU) blends are proposed as PEAP materials due to their range of mechanical properties, thermoformability, and resistance to biodegradation. In this study, the reduction in AAA wall stress that can be achieved using PEAP was estimated and compared to that resulting from stent-grafts. This was accomplished by mechanically modeling the anisotropic response of PCL/PU blends and implementing these results into finite element model (FEM) simulations. We found that at the maximum diameter of the AAA, the 50/50 and 10/90 PCL/PU blends reduced wall stress by 99 and 98%, respectively, while a stent-graft reduced wall stress by 99%. Our results also show that wall stress reduction increases with increasing PEAP thickness and PCL content in the blend ratio. These results indicate that PEAP can reduce AAA wall stress as effectively as a stent-graft. As such, we propose that PEAP may provide an improved treatment alternative for AAA, since many of the limitations of stent-grafts have the potential to be solved using this approach.

Original languageEnglish (US)
Pages (from-to)1680-1689
Number of pages10
JournalAnnals of Biomedical Engineering
Volume39
Issue number6
DOIs
StatePublished - Jun 2011

Fingerprint

Polycaprolactone
Stents
Grafts
Polyurethanes
Biodegradation
Repair
Mechanical properties
Geometry

Keywords

  • AAA
  • Anisotropy
  • Endovascular repair
  • Finite element
  • Polycaprolactone
  • Polyurethane
  • Porohyperelasticity
  • Stent-graft

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Wall stress reduction in abdominal aortic aneurysms as a result of polymeric endoaortic paving. / Ashton, John H.; Ayyalasomayajula, Avinash; Simon, Bruce R.; Vande Geest, Jonathan P.

In: Annals of Biomedical Engineering, Vol. 39, No. 6, 06.2011, p. 1680-1689.

Research output: Contribution to journalArticle

Ashton, John H. ; Ayyalasomayajula, Avinash ; Simon, Bruce R. ; Vande Geest, Jonathan P. / Wall stress reduction in abdominal aortic aneurysms as a result of polymeric endoaortic paving. In: Annals of Biomedical Engineering. 2011 ; Vol. 39, No. 6. pp. 1680-1689.
@article{bf21c71040ce4d00ac17a3baa8f9a248,
title = "Wall stress reduction in abdominal aortic aneurysms as a result of polymeric endoaortic paving",
abstract = "Polymeric endoaortic paving (PEAP) may improve endovascular repair of abdominal aortic aneurysms (AAA) since it has the potential to treat patients with complex AAA geometries while reducing the incidence of migration and endoleak. Polycaprolactone (PCL)/polyurethane (PU) blends are proposed as PEAP materials due to their range of mechanical properties, thermoformability, and resistance to biodegradation. In this study, the reduction in AAA wall stress that can be achieved using PEAP was estimated and compared to that resulting from stent-grafts. This was accomplished by mechanically modeling the anisotropic response of PCL/PU blends and implementing these results into finite element model (FEM) simulations. We found that at the maximum diameter of the AAA, the 50/50 and 10/90 PCL/PU blends reduced wall stress by 99 and 98{\%}, respectively, while a stent-graft reduced wall stress by 99{\%}. Our results also show that wall stress reduction increases with increasing PEAP thickness and PCL content in the blend ratio. These results indicate that PEAP can reduce AAA wall stress as effectively as a stent-graft. As such, we propose that PEAP may provide an improved treatment alternative for AAA, since many of the limitations of stent-grafts have the potential to be solved using this approach.",
keywords = "AAA, Anisotropy, Endovascular repair, Finite element, Polycaprolactone, Polyurethane, Porohyperelasticity, Stent-graft",
author = "Ashton, {John H.} and Avinash Ayyalasomayajula and Simon, {Bruce R.} and {Vande Geest}, {Jonathan P}",
year = "2011",
month = "6",
doi = "10.1007/s10439-011-0271-z",
language = "English (US)",
volume = "39",
pages = "1680--1689",
journal = "Annals of Biomedical Engineering",
issn = "0090-6964",
publisher = "Springer Netherlands",
number = "6",

}

TY - JOUR

T1 - Wall stress reduction in abdominal aortic aneurysms as a result of polymeric endoaortic paving

AU - Ashton, John H.

AU - Ayyalasomayajula, Avinash

AU - Simon, Bruce R.

AU - Vande Geest, Jonathan P

PY - 2011/6

Y1 - 2011/6

N2 - Polymeric endoaortic paving (PEAP) may improve endovascular repair of abdominal aortic aneurysms (AAA) since it has the potential to treat patients with complex AAA geometries while reducing the incidence of migration and endoleak. Polycaprolactone (PCL)/polyurethane (PU) blends are proposed as PEAP materials due to their range of mechanical properties, thermoformability, and resistance to biodegradation. In this study, the reduction in AAA wall stress that can be achieved using PEAP was estimated and compared to that resulting from stent-grafts. This was accomplished by mechanically modeling the anisotropic response of PCL/PU blends and implementing these results into finite element model (FEM) simulations. We found that at the maximum diameter of the AAA, the 50/50 and 10/90 PCL/PU blends reduced wall stress by 99 and 98%, respectively, while a stent-graft reduced wall stress by 99%. Our results also show that wall stress reduction increases with increasing PEAP thickness and PCL content in the blend ratio. These results indicate that PEAP can reduce AAA wall stress as effectively as a stent-graft. As such, we propose that PEAP may provide an improved treatment alternative for AAA, since many of the limitations of stent-grafts have the potential to be solved using this approach.

AB - Polymeric endoaortic paving (PEAP) may improve endovascular repair of abdominal aortic aneurysms (AAA) since it has the potential to treat patients with complex AAA geometries while reducing the incidence of migration and endoleak. Polycaprolactone (PCL)/polyurethane (PU) blends are proposed as PEAP materials due to their range of mechanical properties, thermoformability, and resistance to biodegradation. In this study, the reduction in AAA wall stress that can be achieved using PEAP was estimated and compared to that resulting from stent-grafts. This was accomplished by mechanically modeling the anisotropic response of PCL/PU blends and implementing these results into finite element model (FEM) simulations. We found that at the maximum diameter of the AAA, the 50/50 and 10/90 PCL/PU blends reduced wall stress by 99 and 98%, respectively, while a stent-graft reduced wall stress by 99%. Our results also show that wall stress reduction increases with increasing PEAP thickness and PCL content in the blend ratio. These results indicate that PEAP can reduce AAA wall stress as effectively as a stent-graft. As such, we propose that PEAP may provide an improved treatment alternative for AAA, since many of the limitations of stent-grafts have the potential to be solved using this approach.

KW - AAA

KW - Anisotropy

KW - Endovascular repair

KW - Finite element

KW - Polycaprolactone

KW - Polyurethane

KW - Porohyperelasticity

KW - Stent-graft

UR - http://www.scopus.com/inward/record.url?scp=79958865836&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79958865836&partnerID=8YFLogxK

U2 - 10.1007/s10439-011-0271-z

DO - 10.1007/s10439-011-0271-z

M3 - Article

C2 - 21350892

AN - SCOPUS:79958865836

VL - 39

SP - 1680

EP - 1689

JO - Annals of Biomedical Engineering

JF - Annals of Biomedical Engineering

SN - 0090-6964

IS - 6

ER -