Based on a single-chip DSP (TMS320C25, Texas Instruments) a programmable battery-operated sound processor with a digital encoder interface for the Nucleus-22 cochlear implant (CI) was built. The number of quasi-simultaneously adressed electrodes is only limited by the selected pulse width and the maximum rate of stimulation and can be as high as 10 electrodes at 300 Hz repetition rate. Implementation of various processing strategies (formant or channel vocoder, filtebank, zero crossings, etc.) is possible as well as sophisticated adaptive noise reduction. Programs and stimulation parameters are stored in electrically erasable memory and may be updated via a host computer. The built-in analog output may be used for single-channel stimulation or acoustic verifications of the sound processed algorithms. The power consumption with current 16K word data memory and at amximum stimulation rate is about 1 Watt, which necessitates recharging of batteries after 11 h.

Original languageEnglish (US)
Pages (from-to)120-127
Number of pages8
JournalActa Oto-Laryngologica, Supplement
Issue number469
StatePublished - 1990
Externally publishedYes

Fingerprint

Cochlear Implants
Electrodes
Acoustic Stimulation
Noise
Power (Psychology)

Keywords

  • auditory prosthesis
  • electrical stimulation
  • vocoder

ASJC Scopus subject areas

  • Otorhinolaryngology

Cite this

Wearable digital speech processor for cochlear implants using a TMS320C25. / Dillier, N.; Senn, C.; Schlatter, T.; Stockli, M.; Utzinger, Urs.

In: Acta Oto-Laryngologica, Supplement, No. 469, 1990, p. 120-127.

Research output: Contribution to journalArticle

Dillier, N. ; Senn, C. ; Schlatter, T. ; Stockli, M. ; Utzinger, Urs. / Wearable digital speech processor for cochlear implants using a TMS320C25. In: Acta Oto-Laryngologica, Supplement. 1990 ; No. 469. pp. 120-127.
@article{356e2f40ce144b64b970903056b963be,
title = "Wearable digital speech processor for cochlear implants using a TMS320C25",
abstract = "Based on a single-chip DSP (TMS320C25, Texas Instruments) a programmable battery-operated sound processor with a digital encoder interface for the Nucleus-22 cochlear implant (CI) was built. The number of quasi-simultaneously adressed electrodes is only limited by the selected pulse width and the maximum rate of stimulation and can be as high as 10 electrodes at 300 Hz repetition rate. Implementation of various processing strategies (formant or channel vocoder, filtebank, zero crossings, etc.) is possible as well as sophisticated adaptive noise reduction. Programs and stimulation parameters are stored in electrically erasable memory and may be updated via a host computer. The built-in analog output may be used for single-channel stimulation or acoustic verifications of the sound processed algorithms. The power consumption with current 16K word data memory and at amximum stimulation rate is about 1 Watt, which necessitates recharging of batteries after 11 h.",
keywords = "auditory prosthesis, electrical stimulation, vocoder",
author = "N. Dillier and C. Senn and T. Schlatter and M. Stockli and Urs Utzinger",
year = "1990",
language = "English (US)",
pages = "120--127",
journal = "Acta Oto-Laryngologica, Supplement",
issn = "0365-5237",
publisher = "Taylor and Francis Ltd.",
number = "469",

}

TY - JOUR

T1 - Wearable digital speech processor for cochlear implants using a TMS320C25

AU - Dillier, N.

AU - Senn, C.

AU - Schlatter, T.

AU - Stockli, M.

AU - Utzinger, Urs

PY - 1990

Y1 - 1990

N2 - Based on a single-chip DSP (TMS320C25, Texas Instruments) a programmable battery-operated sound processor with a digital encoder interface for the Nucleus-22 cochlear implant (CI) was built. The number of quasi-simultaneously adressed electrodes is only limited by the selected pulse width and the maximum rate of stimulation and can be as high as 10 electrodes at 300 Hz repetition rate. Implementation of various processing strategies (formant or channel vocoder, filtebank, zero crossings, etc.) is possible as well as sophisticated adaptive noise reduction. Programs and stimulation parameters are stored in electrically erasable memory and may be updated via a host computer. The built-in analog output may be used for single-channel stimulation or acoustic verifications of the sound processed algorithms. The power consumption with current 16K word data memory and at amximum stimulation rate is about 1 Watt, which necessitates recharging of batteries after 11 h.

AB - Based on a single-chip DSP (TMS320C25, Texas Instruments) a programmable battery-operated sound processor with a digital encoder interface for the Nucleus-22 cochlear implant (CI) was built. The number of quasi-simultaneously adressed electrodes is only limited by the selected pulse width and the maximum rate of stimulation and can be as high as 10 electrodes at 300 Hz repetition rate. Implementation of various processing strategies (formant or channel vocoder, filtebank, zero crossings, etc.) is possible as well as sophisticated adaptive noise reduction. Programs and stimulation parameters are stored in electrically erasable memory and may be updated via a host computer. The built-in analog output may be used for single-channel stimulation or acoustic verifications of the sound processed algorithms. The power consumption with current 16K word data memory and at amximum stimulation rate is about 1 Watt, which necessitates recharging of batteries after 11 h.

KW - auditory prosthesis

KW - electrical stimulation

KW - vocoder

UR - http://www.scopus.com/inward/record.url?scp=0025196106&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025196106&partnerID=8YFLogxK

M3 - Article

SP - 120

EP - 127

JO - Acta Oto-Laryngologica, Supplement

JF - Acta Oto-Laryngologica, Supplement

SN - 0365-5237

IS - 469

ER -